English
Language : 

W83637HF Datasheet, PDF (63/149 Pages) Winbond – LPC I/O
W83637HF
VTIN Temperature Sensor Temperature (Low Byte) Register - Index 51h (Bank 2)
Register Location:
51h
Attribute:
Read Only
Size:
8 bits
7 6 5 4 32 1 0
Reserved
TEMP<0>
Bit 7: Temperature <0> of sensor3, which is low byte, means 0.5°C.
Bit 6-0: Reserved.
VTIN Temperature Sensor Configuration Register - Index 52h (Bank 2)
Register Location:
52h
Power on Default Value
00h
Size:
8 bits
7 65432 1 0
STOP
OVTMOD
Reserved
FAULT
FAULT
Reserved
Reserved
Reserved
Bit 7-5: Read - Reserved. This bit should be set to 0.
Bit 4-3: Read/Write - Number of faults to detect before setting OVT# output to avoid false tripping due
to noise.
Bit 2: Read - Reserved. This bit should be set to 0.
Bit 1: Read/Write - OVT# mode select. This bit default is set to 0, which is compared mode. When set
to 1, interrupt mode will be selected.
Bit 0: Read/Write - When set to 1 the sensor will stop monitor.
- 58 -
Publication Release Date: June 25, 2003
Revision 1.3