6.6.3 The W83637HF temperature sensor 1(SYSTIN) SMI# interrupt has two modes
(1) Comparator Interrupt Mode
Setting the THYST (Temperature Hysteresis) limit to 127°C will set temperature sensor 1 SMI# to
the Comparator Interrupt Mode. Temperature exceeds TO (Over Temperature) Limit causes an
interrupt and this interrupt will be reset by reading all the Interrupt Status Register. Once an
interrupt event has occurred by exceeding TO, then reset, if the temperature remains above the
TO, the interrupt will occur again when the next conversion has completed. If an interrupt event
has occurred by exceeding TO and not reset, the interrupts will not occur again. The interrupts will
continue to occur in this manner until the temperature goes below TO. (Figure 6.11)
Setting the THYST lower than TO will set temperature sensor 1 SMI# to the Interrupt Mode. The following
are two kinds of interrupt modes, which are selected by Index 4Ch bit5:
(2) Two-Times Interrupt Mode
Temperature exceeding TO causes an interrupt and then temperature going below THYST will also
cause an interrupt if the previous interrupt has been reset by reading all the interrupt Status
Register. Once an interrupt event has occurred by exceeding TO, then reset, if the temperature
remains above the THYST, the interrupt will not occur. (Figure 6.12)
(3) One-Time Interrupt Mode
Temperature exceeding TO causes an interrupt and then temperature going below THYST will not
cause an interrupt. Once an interrupt event has occurred by exceeding TO, then going below
THYST, an interrupt will not occur again until the temperature exceeding TO. (Figure .6.13)
THYST
127'C
TOI
TOI
THYST
SMI#
*
*
*
SMI#
*
*
*
*
*Interrupt Reset when Interrupt Status Registers are read
Figure 6.11
Figure 6.12
- 35 -
Publication Release Date: June 25, 2003
Revision 1.3