W83637HF Datasheet, PDF (41/149 Pages) Winbond – LPC I/O
W83637HF
TOI
THYST
SMI#
*
*
*Interrupt Reset when Interrupt Status Registers are read
Figure 6.13
6.6.4 The W83637HF temperature sensor 2(CPUTIN) and sensor 3(VTIN) SMI#
interrupt has two modes and it is programmed at CR[4Ch] bit 6.
(1) Comparator Interrupt Mode
Temperature exceeding TO causes an interrupt and this interrupt will be reset by reading all the
Interrupt Status Register. Once an interrupt event has occurred by exceeding TO, then reset, if the
temperature remains above the THYST, the interrupt will occur again when the next conversion has
completed. If an interrupt event has occurred by exceeding TO and not reset, the interrupts will not
occur again. The interrupts will continue to occur in this manner until the temperature goes below
THYST. (Figure 6.14)
(2) Two-Times Interrupt Mode
Temperature exceeding TO causes an interrupt and then temperature going below THYST will also
cause an interrupt if the previous interrupt has been reset by reading all the interrupt Status
Register. Once an interrupt event has occurred by exceeding TO, then reset, if the temperature
remains above the THYST, the interrupt will not occur. (Figure 6.15)
TOI
TOI
THYST
THYST
SMI#
*
*
**
SMI#
*
*
*
*
Figure 6.14
*Interrupt Reset when Interrupt Status Registers are read
Figure 6.15
- 36 -
Publication Release Date: June 25, 2003
Revision 1.3