English
Language : 

DS90C124_13 Datasheet, PDF (6/31 Pages) Texas Instruments – 5-MHz to 35-MHz DC-Balanced 24-Bit FPD-Link II Serializer and Deserializer
DS90C124, DS90C241
SNLS209L – NOVEMBER 2005 – REVISED APRIL 2013
www.ti.com
Serializer Timing Requirements for TCLK
Over recommended operating supply and temperature ranges unless otherwise specified.
Symbol
Parameter
Conditions
Min
Typ
tTCP
tTCIH
tTCIL
tCLKT
tJIT
Transmit Clock Period
Transmit Clock High Time
Transmit Clock Low Time
TCLK Input Transition Time
TCLK Input Jitter
(Figure 5)
(Figure 4)
(1)
28.6
0.4T
0.4T
T
0.5T
0.5T
3
(1) tJIT (at BER of 10e-9) specifies the allowable jitter on TCLK. tJIT not included in TxOUT_E_O parameter.
Max
200
0.6T
0.6T
6
33
Units
ns
ns
ns
ns
ps (RMS)
Serializer Switching Characteristics
Over recommended operating supply and temperature ranges unless otherwise specified.
Symbol
Parameter
Conditions
Min
Typ
Max
Units
tLLHT
tLHLT
LVDS Low-to-High Transition Time
LVDS High-to-Low Transition Time
RL = 100Ω, (Figure 3)
CL = 10 pF to GND
VODSEL = L
0.6
ns
0.6
ns
tDIS
DIN (23:0) Setup to TCLK
RL = 100Ω,
5
ns
tDIH
DIN (23:0) Hold from TCLK
CL = 10 pF to GND
(1)
5
ns
tHZD
DOUT ± HIGH to TRI-STATE Delay
tLZD
DOUT ± LOW to TRI-STATE Delay
tZHD
DOUT ± TRI-STATE to HIGH Delay
tZLD
DOUT ± TRI-STATE to LOW Delay
tPLD
Serializer PLL Lock Time
tSD
Serializer Delay
TxOUT_ TxOUT_Eye_Opening
E_O
(respect to ideal)
RL = 100Ω,
CL = 10 pF to GND
(Figure 6)(2)
RL = 100Ω, (Figure 7)
RL = 100Ω, (Figure 8)
VODSEL = L, TRFB = H
RL = 100Ω, (Figure 8)
VODSEL = L, TRFB = L
5–35 MHz
(Figure 9)(1) (3) (4)
15
ns
15
ns
200
ns
200
ns
10
ms
3.5T +
2.85
3.5T + 10
ns
3.5T +
2.85
3.5T + 10
ns
0.75
UI (5)
(1) Specification is ensured by characterization and is not tested in production.
(2) When the Serializer output is tri-stated, the Deserializer will lose PLL lock. Resynchronization MUST occur before data transfer.
(3) tJIT (at BER of 10e-9) specifies the allowable jitter on TCLK. tJIT not included in TxOUT_E_O parameter.
(4) TxOUT_E_O is affected by pre-emphasis value.
(5) UI – Unit Interval, equivalent to one ideal serialized data bit width. The UI scales with frequency.
6
Submit Documentation Feedback
Copyright © 2005–2013, Texas Instruments Incorporated
Product Folder Links: DS90C124 DS90C241