AC Electrical Characteristics (continued)
Over recommended operating supply and temperature ranges unless otherwise specified. (1) (2) (3)
PARAMETER
TEST CONDITIONS
PIN/FREQ.
MIN TYP
TLC
I2S Clock Low Time
Figure 10, (6)
I2S_CLK
0.35
tSR_I2S
I2S Set-up Time
Figure 10, (6)
I2S_WC
0.2
I2S_D[A:D]
tHR_I2S
I2S Hold Time
Figure 10, (6)
I2S_WC
0.2
I2S_D[A:D]
www.ti.com
MAX UNIT
TI2S
TI2S
TI2S
7.7 Timing Requirements for the Serial Control Bus
Over 3.3-V supply and temperature ranges unless otherwise specified. (1) (2)
fSCL
tLOW
tHIGH
tHD;STA
SCL Clock Frequency
SCL Low Period
SCL High Period
Hold time for a start or a
repeated start condition
(3)
Standard Mode
Fast Mode
Standard Mode
Fast Mode
Standard Mode
Fast Mode
Standard Mode
Fast Mode
MIN TYP MAX UNIT
0
100 kHz
0
400 kHz
4.7
µs
1.3
µs
4.0
µs
0.6
µs
4.0
µs
0.6
µs
tSU:STA
Set Up time for a start or a
repeated start condition
(3)
Standard Mode
Fast Mode
4.7
µs
0.6
µs
tHD;DAT
tSU;DAT
tSU;STO
Data Hold Time
(3)
Data Set Up Time
(3)
Set Up Time for STOP
Condition
(3)
Standard Mode
Fast Mode
Standard Mode
Fast Mode
Standard Mode
Fast Mode
0
3.45 µs
0
0.9 µs
250
ns
100
ns
4
µs
0.6
µs
Bus Free Time
Standard Mode
tBUF
Between STOP and START
(3)
Fast Mode
4.7
µs
1.3
µs
tr
SCL & SDA Rise Time,
(3)
Standard Mode
Fast Mode
tf
SCL & SDA Fall Time,
(3)
Standard Mode
Fast mode
1000 ns
300 ns
300 ns
300 ns
(1) The Electrical Characteristics tables list ensured specifications under the listed Recommended Operating Conditions except as
otherwise modified or specified by the Electrical Characteristics conditions and/or notes. Typical specifications are estimations only and
are not ensured.
(2) Typical values represent most likely parametric norms at VDD33 = 3.3 V, VDDIO = 1.8 V or 3.3 V, TA = +25°C, and at the Recommended
Operating Conditions at the time of product characterization and are not ensured.
(3) Specification is ensured by design and is not tested in production.
7.8 Timing Requirements
tR
tF
tSU;DAT
tHD;DAT
SDA RiseTime – READ
SDA Fall Time – READ
Set Up Time – READ
Hold Up Time – READ
SDA, RPU = 10 kΩ, Cb ≤
400 pF, Figure 16
Figure 16
Figure 16
MIN
NOM
MAX UNIT
430
ns
20
ns
560
ns
615
ns
12