English
Language : 

CC430F5125 Datasheet, PDF (80/118 Pages) Texas Instruments – MSP430 SoC With RF Core
CC430F614x
CC430F514x
CC430F512x
ECCN 5E002 TSPA - Technology / Software Publicly Available
SLAS555A – NOVEMBER 2012 – REVISED FEBRUARY 2013
www.ti.com
Typical Output Power, 315 MHz(1)
PARAMETER
PATABLE Setting
Output power,
315 MHz
0xC0 (max)
0xC4 (10 dBm)
0xC6 (default)
0x51 (0 dBm)
0x29 (-6 dBm)
VCC
2.0 V
3.0 V
3.6 V
UNIT
TA -40°C 25°C 85°C -40°C 25°C 85°C -40°C 25°C 85°C
11.9
11.8
11.8
10.3
10.3
10.3
9.3
dBm
0.7
0.6
0.7
-6.8
-5.6
-5.3
(1) All measurement results are obtained using the EM430F6137RF900 with BOM according to tested frequency range (see Table 49).
Typical Output Power, 433 MHz(1)
PARAMETER
PATABLE Setting
Output power,
433 MHz
0xC0 (max)
0xC4 (10 dBm)
0xC6 (default)
0x50 (0 dBm)
0x2D (-6 dBm)
VCC
2.0 V
3.0 V
3.6 V
UNIT
TA -40°C 25°C 85°C -40°C 25°C 85°C -40°C 25°C 85°C
12.6
12.6
12.6
10.3
10.2
10.2
10.0
dBm
0.3
0.3
0.3
-6.4
-5.4
-5.1
(1) All measurement results are obtained using the EM430F6137RF900 with BOM according to tested frequency range (see Table 49).
Typical Output Power, 868 MHz(1)
PARAMETER
PATABLE Setting
0xC0 (max)
VCC
2.0 V
3.0 V
3.6 V
UNIT
TA -40°C 25°C 85°C -40°C 25°C 85°C -40°C 25°C 85°C
11.9 11.2 10.5 11.9 11.2 10.5 11.9 11.2 10.5
Output power,
868 MHz
0xC3 (10 Bm)
0xC6 (default)
0x8D (0 dBm)
10.8 10.1 9.4 10.8 10.1 9.4 10.7 10.1 9.4
8.8
dBm
1.0 0.3 -0.3 1.1 0.3 -0.3 1.1 0.3 -0.3
0x2D (-6 dBm)
-6.5 -6.8 -7.3 -5.3 -5.8 -6.3 -4.9 -5.4 -6.0
(1) All measurement results are obtained using the EM430F6137RF900 with BOM according to tested frequency range (see Table 49).
Typical Output Power, 915 MHz(1)
PARAMETER
PATABLE Setting
0xC0 (max)
VCC
2.0 V
3.0 V
3.6 V
UNIT
TA -40°C 25°C 85°C -40°C 25°C 85°C -40°C 25°C 85°C
12.2 11.4 10.6 12.1 11.4 10.7 12.1 11.4 10.7
Output power,
915 MHz
0xC3 (10 dBm)
0xC6 (default)
0x8D (0 dBm)
11.0 10.3 9.5 11.0 10.3 9.5 11.0 10.3 9.6
8.8
dBm
1.9 1.0 0.3 1.9 1.0 0.3 1.9 1.1 0.3
0x2D (-6 dBm)
-5.5 -6.0 -6.5 -4.3 -4.8 -5.5 -3.9 -4.4 -5.1
(1) All measurement results are obtained using the EM430F6137RF900 with BOM according to tested frequency range (see Table 49).
80
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated