4. Electrical Specifications
4. Electrical Specifications
4.1 Terminology
Table4.1 Terms Used in Absolute Maximum Ratings
Parameter
Power supply voltage
Input voltage
Output voltage
Output current
Operating ambient
temperature
Storage temperature
Symbol
VDD
VI
VO
IO
TA
Meaning
Indicates the voltage range within which damage or reduced reliability will not
result when power is applied to a VDD pin.
Indicates the voltage range within which damage or reduced reliability will not
result when power is applied to an input pin.
Indicates the voltage range within which damage or reduced reliability will not
result when power is applied to an output pin.
Indicates the absolute tolerance value for DC current to prevent damage or
reduced reliability when a current flows out of or into an output pin.
Indicates the ambient temperature range for normal logic operations.
Tstg
Indicates the element temperature range within which damage or reduced
reliability will not result while no voltage or current is being applied to the device.
Table4.2 Terms Used in Recommended Operating Range Ratings
Parameter
Power supply voltage
Input voltage, high
Symbol
VDD
VIH
Input voltage, low
VIL
Positive trigger voltage VP
Negative trigger voltage VN
Hysteresis Voltage
VH
Input rise time
trid,
tric,
tris
Input fall time
tfid,
tfic,
tfis
Meaning
Indicates the voltage range for normal logic operations that occur when VSS = 0 V.
Indicates the voltage, which is applied to the input pins of R-IN32M3, is the voltage
indicates that the high level state for normal operation of the input buffer.
-If a voltage that is equal to or greater than the “Min.” value is applied, the input
voltage is guaranteed as a high level voltage.
Indicates the voltage, which is applied to the input pins of R-IN32M3, is the voltage
indicates that the low level state for normal operation of the input buffer.
-If a voltage that is equal to or less than the “Max.” value is applied, the input
voltage is guaranteed as a low level voltage.
Indicates the input level at which the output level is inverted when the input to
R-IN32M3 is changed from the low-level side to the high-level side.
Indicates the input level at which the output level is inverted when the input to
R-IN32M3 is changed from the high-level side to the low-level side.
Indicates the differential between the positive trigger voltage and the negative
trigger voltage.
Indicates the limit value for the time period when an input voltage applied to
R-IN32M3 rises from 10% to 90%. trid, tric, and tris each indicate the input rise
time for the data clock and Schmitt buffer.
Indicates the limit value for the time period when an input voltage applied to
R-IN32M3 falls from 90% to 10%. trid, tric, and tris each indicate the input fall time
for the data clock and Schmitt buffer.
R18DS0008EJ0204