English
Language : 

RX110_16 Datasheet, PDF (64/108 Pages) Renesas Technology Corp – 32 MHz 32-bit RX MCUs, 50 DMIPS
RX110 Group
5. Electrical Characteristics
Table 5.22 Clock Timing
Conditions: 1.8 V ≤ VCC ≤ 3.6 V, 1.8 V ≤ AVCC0 ≤ 3.6 V, VSS = AVSS0 = 0 V, Ta = –40 to +105°C
Item
Symbol Min. Typ. Max.
XTAL external clock input cycle time
tXcyc
50
—
—
XTAL external clock input high pulse width
tXH
20
—
—
XTAL external clock input low pulse width
tXL
20
—
—
XTAL external clock rising time
tXr
—
—
5
XTAL external clock falling time
tXf
—
—
5
XTAL external clock input wait time*1
tEXWT
0.5
—
—
Main clock oscillator oscillation frequency
2.4 ≤ VCC ≤ 3.6
fMAIN
1
—
20
1.8 ≤ VCC < 2.4
1
—
8
Main clock oscillation stabilization time (crystal)*2
tMAINOSC
—
3
—
Main clock oscillation stabilization time (ceramic resonator)*2
tMAINOSC
—
50
LOCO clock oscillation frequency
fLOCO
3.44
4.0
4.56
LOCO clock oscillation stabilization time
tLOCO
—
—
0.5
IWDT-dedicated clock oscillation frequency
fILOCO 12.75
15
17.25
IWDT-dedicated clock oscillation stabilization time
tILOCO
—
—
50
HOCO clock oscillation frequency
fHOCO 31.52
32
32.48
31.68 32 32.32
31.36 32 32.64
HOCO clock oscillation stabilization time
Sub-clock oscillator oscillation frequency*4
tHOCO2
fSUB
—
—
56
— 32.768 —
Sub-clock oscillation stabilization time*3
tSUBOSC
—
0.5
—
Unit Test Conditions
ns Figure 5.18
ns
ns
ns
ns
µs
MHz
ms Figure 5.20
µs
MHz
µs Figure 5.21
kHz
μs Figure 5.19
MHz Ta = –40 to 85°C
Ta = –20 to 85°C
Ta = –40 to 105°C
µs Figure 5.23
kHz
s Figure 5.24
Note 1. Time until the clock can be used after the main clock oscillator stop bit (MOSCCR.MOSTP) is set to 0 (operating) when the
external clock is stable.
Note 2. Reference values when an 8-MHz oscillator is used.
When specifying the main clock oscillator stabilization time, set the MOSCWTCR register with a stabilization time value that is
equal to or greater than the oscillator-manufacturer-recommended value.
After changing the setting of the MOSCCR.MOSTP bit so that the main clock oscillator operates, read the OSCOVFSR.MOOVF
flag to confirm that is has become 1, and then start using the main clock.
Note 3. After changing the setting of the SOSCCR.SOSTP bit or RCR3.RTCEN bit so that the sub-clock oscillator operates, only start
using the sub-clock after the sub-clock oscillation stabilization wait time that is equal to or greater than the oscillator-
manufacturer-recommended value has elapsed.
Reference value when a 32.768-kHz resonator is used.
Note 4. Only 32.768 kHz can be used.
tEXH
tEXcyc
tEXL
XTAL external clock input
tEXr
tEXf
Figure 5.18 XTAL External Clock Input Timing
VCC × 0.5
R01DS0202EJ0120 Rev.1.20
Jul 29, 2016
Page 64 of 108