PIC16LC63A-04 Datasheet, PDF (138/184 Pages) Microchip Technology – 8-Bit CMOS Microcontrollers with A/D Converter
PIC16C63A/65B/73B/74B
FIGURE 16-20: A/D CONVERSION TIMING
BSF ADCON0, GO
134
(TOSC/2)(1)
131
Q4
130
A/D CLK 132
1 TCY
A/D DATA
7
6
5
4
3
2
1
0
ADRES
OLD_DATA
NEW_DATA
ADIF
GO
DONE
SAMPLE
SAMPLING STOPPED
Note 1: If the A/D clock source is selected as RC, a time of TCY is added before the A/D clock starts. This allows the SLEEP
instruction to be executed.
TABLE 16-17: A/D CONVERSION REQUIREMENTS
Param
No.
Sym
Characteristic
Min Typ† Max Units
Conditions
130 TAD A/D clock period
PIC16CXX
1.6
—
— µs TOSC based, VREF ≥ 3.0 V
PIC16LCXX 2.0
—
— µs TOSC based,
2.5V ≤ VREF ≤ 5.5 V
PIC16CXX
2.0 4.0 6.0 µs A/D RC mode
PIC16LCXX 3.0 6.0 9.0 µs A/D RC mode
131 TCNV Conversion time (not including S/H
time) (Note 1)
11
—
11 TAD
132 TACQ Acquisition time
5*
—
— µs The minimum time is the
amplifier settling time. This
may be used if the “new”
input voltage has not
changed by more than 1 LSb
(i.e., 20.0mV @ 5.12V) from
the last sampled voltage (as
stated on CHOLD).
134 TGO Q4 to A/D clock start
— TOSC/2 —
— If the A/D clock source is
selected as RC, a time of TCY
is added before the A/D clock
starts. This allows the SLEEP
instruction to be executed.
135 TSWC Switching from convert → sample time 1.5
—
— TAD
* These parameters are characterized but not tested.
† Data in “Typ” column is at 5V, 25°C unless otherwise stated. These parameters are for design guidance only and
are not tested.
Note 1: ADRES register may be read on the following TCY cycle.
2: See Section 12.1 for minimum conditions.
DS30605C-page 138
 2000 Microchip Technology Inc.