English
Language : 

71M6533 Datasheet, PDF (32/132 Pages) Teridian Semiconductor Corporation – Energy Meter IC
71M6533/G/H and 71M6534/H Data Sheet
FDS_6533_6534_004
Bit
TCON[7]
TCON[6]
TCON[5]
TCON[4]
TCON[3]
TCON[2]
TCON[1]
TCON[0]
Table 27: TCON Bit Functions (SFR 0x88)
Symbol
TF1
TR1
TF0
TR0
IE1
IT1
IE0
IT0
Function
Timer 1 overflow flag.
Not used for interrupt control.
Timer 0 overflow flag.
Not used for interrupt control.
External interrupt 1 flag.
External interrupt 1 type control bit:
0 = interrupt on low level.
1 = interrupt on falling edge.
External interrupt 0 flag
External interrupt 0 type control bit:
0 = interrupt on low level.
1 = interrupt on falling edge.
Table 28: The T2CON Bit Functions (SFR 0xC8)
Bit
T2CON[7]
T2CON[6]
T2CON[5]
T2CON[4:0]
Symbol
–
I3FR
I2FR
–
Function
Not used.
Polarity control for external interrupt 3: CE_BUSY
0 = falling edge.
1 = rising edge.
Polarity control for external interrupt 2: FWCOL0, FWCOL1, SPI
0 = falling edge.
1 = rising edge.
Not used.
Bit
IRCON[7]
IRCON[6]
IRCON[5]
IRCON[4]
IRCON[3]
IRCON[2]
IRCON[1]
IRCON[0]
Table 29: The IRCON Bit Functions (SFR 0xC0)
Symbol
–
–
IEX6
IEX5
IEX4
IEX3
IEX2
–
Function
Not used
Not used
1 = External interrupt 6 occurred and has not been cleared.
1 = External interrupt 5 occurred and has not been cleared.
1 = External interrupt 4 occurred and has not been cleared.
1 = External interrupt 3 occurred and has not been cleared.
1 = External interrupt 2 occurred and has not been cleared.
Not used.
TF0 and TF1 (Timer 0 and Timer 1 overflow flags) will be automatically cleared by hardware when
the service routine is called (Signals T0ACK and T1ACK – port ISR – active high when the service
routine is called).
32
Rev 2