applying power to V1/VCC). The input voltage is decreased,
and found to trip the associated output level of pin V2RO from a
LOW to a HIGH, when V2 reaches 3.09 V. From this, it can be
calculated that the programming error is 3.09 - 3.0 = 0.09 V.
If the error between the desired and measured VTRIPx is
less than the maximum desired error, then the programming
process may be terminated. If however, the error is greater
than the maximum desired error, then another iteration of the
VTRIPx programming sequence can be performed (using the
calculated error) in order to further increase the accuracy of
the threshold voltage.
If the calculated error is greater than zero, then the VTRIPx
must first be “reset”, and then programmed to the a value equal
to the previously set VTRIPx minus the calculated error. If it is
the case that the error is less than zero, then the VTRIPx must
be programmed to a value equal to the previously set VTRIPx
plus the absolute value of the calculated error.
Continuing the previous example, we see that the calculated
error was 0.09V. Since this is greater than zero, we must first
“reset” the VTRIP2 threshold, then apply a voltage equal to the
last previously programmed voltage, minus the last previously
calculated error. Therefore, we must apply VTRIP2 = 2.91 V to
pin V2 and execute the programming sequence.
Using this process, the desired accuracy for a particular
VTRIPx threshold may be attained using a successive
number of iterations.
VTRIPx Programming
Note: X = 1,2,3.
Let: MDE = Maximum Desired Error
New Vx applied =
Old Vx applied + | Error |
NO
Desired VTRIPx <
present value?
YES
Execute
VTRIPx Reset
Sequence
Set Vx = desired VTRIPx
Execute
Set Higher VTRIPx
Sequence
MDE+
Desired Value
MDE–
Acceptable
Error Range
Error = Actual - Desired
New Vx applied =
Old Vx applied - | Error |
Apply VCC & Voltage
> Desired VTRIPx to Vx
Execute
Reset VTRIPx
Sequence
Decrease Vx
NO
Output
switches?
YES
Error < MDE–
-
Actual VTRIPx
Desired VTRIPx
= Error
Error >MDE+
| Error | < | MDE |
DONE
FIGURE 24. VTRIPx SETTING/RESET SEQUENCE (X = 1,2,3)