English
Language : 

NQ41210SL7JE Datasheet, PDF (18/52 Pages) Intel Corporation – Intel® 41210 Serial to Parallel PCI Bridge
41210 Bridge — Datasheet
3.1.2
Table 11.
Input Characteristic Signal Association
DC Characteristics Input Signal Association
Symbol
VIH1/VIL1
VIH2/VIL2
VIH3/VIL3
Signals
Interrupt Signals: A_IRQ[15:0]#, B_IRQ[15:0]#
PCI Signals: A_AD[63:0], B_AD[63:0], A_CBE[7:0]#, B_CBE[7:0]#, A_PAR, B_PAR,
A_DEVSEL#, B_DEVSEL#, A_FRAME#, B_FRAME#, A_IRDY#, B_IRDY#, A_TRDY#,
B_TRDY#, A_STOP#, B_STOP#, A_PERR#, B_PERR#, A_SERR#, B_SERR#, A_REQ[5:0]#,
B_REQ[5:0]#, A_M66EN, B_M66EN, A_133EN, B_133EN, A_PCIXCAP, B_PCIXCAP,
A_PAR64, B_PAR64, A_REQ64#, B_REQ64#, A_ACK64#, B_ACK64#
Clock Signals (3.3 V Only): A_CLKI, B_CLKI
Miscellaneous Signals: PERST#
PCI Express Signals: REFCLK, REFCLK#, PETP[7:0], PETN[7:0], PE_RCOMP[1:0]
SMB Signals: SMBDAT, SMBCLK
3.1.3
Table 12.
DC Input Characteristics
DC Input Characteristics
Symbol
Parameter
VIL1
VIH1
Symbol
VIL2
VIH2
VIL3
VIH3
Input Low Voltage
Input High Voltage
Parameter
Input Low Voltage
Input High Voltage
Input Low Voltage
Input High Voltage
3.3 V Signal
Unit
Min
Max
-0.5
0.5 VCC33
0.35 VCC33 V
VCC33 +0.5 V
Max
N/A
V
N/A
V
0.6
V
VCC33 + 0.5
V
3.1.4
Table 13.
DC Characteristic Output Signal Association
DC Characteristic Output Signal Association
Symbol
VOH1/VOL1
VOH2/VOL2
VOH3/VOL3
Signals
PCI Signals: A_AD[63:0], B_AD[63:0], A_CBE[7:0]#, B_CBE[7:0]#, A_PAR, B_PAR,
A_DEVSEL#, B_DEVSEL#, A_FRAME#, B_FRAME#, A_IRDY#, B_IRDY#, A_TRDY#,
B_TRDY#, A_STOP#, B_STOP#, A_PERR#, B_PERR#, A_M66EN, B_M66EN,
A_GNT[6:0]#, B_GNT[5:0]#, A_LOCK#, B_LOCK#, A_PAR64, B_PAR64, A_REQ64#,
B_REQ64#, A_ACK64#, B_ACK64#
PCI Clock Signals (3.3 V Only): A_CLKO[6:0], B_CLKO[6:0], A_RST#, B_RST#
Miscellaneous Signals: RASERR#
PCI Express Signals: PERP[7:0], PERN[7:0]
SMBus Signals: SMBDAT, SMBCLK
18