7.3
Electrical Characteristics
TLE9261-3QX
Voltage Regulator 2
Table 17 Electrical Characteristics
VS = 5.5 V to 28 V; Tj = -40 °C to +150 °C; all voltages with respect to ground, positive current flowing into pin
(unless otherwise specified)
Parameter
Symbol
Values
Unit Note / Test Condition Number
Output Voltage including line
and Load regulation
(SBC Normal Mode)
VCC2,out1
Min. Typ. Max.
4.9 5.0 5.1 V
1)SBC Normal Mode;
10µA < IVCC2 < 100mA
6.5V < VS < 28V
P_7.3.1
Output Voltage including line VCC2,out2 4.9 5.0 5.1 V
and Load regulation
(SBC Normal Mode)
1)SBC Normal Mode; P_7.3.16
10µA < IVCC2 < 80mA
6V < VS < 28V
Output Voltage including line VCC2,out3 4.9 5.0 5.1 V
and Load regulation
(SBC Normal Mode)
1)SBC Normal Mode;
10µA < IVCC2 < 40mA
P_7.3.2
Output Voltage including line
and Load regulation
(SBC Normal Mode)
VCC2,out4
4.97 –
5.07 V
Output Voltage including line VCC2,out5 4.9 5.05 5.2 V
and Load regulation
(SBC Stop/Sleep Mode)
2)SBC Normal Mode; P_7.3.14
10µA < IVCC2 < 5mA
8V < VS < 18V
25°C < Tj < 125°C
Stop, Sleep Mode;
P_7.3.3
1mA < IVCC2 < IVCC2,Ipeak
Output Voltage including line VCC2,out6 4.9
and Load regulation
(SBC Stop/Sleep Mode)
5.05 5.25 V
Stop, Sleep Mode;
10µA < IVCC2 < 1mA
P_7.3.18
Output Drop
VCC2,d1
–
VCC2 Active Peak Threshold
(Transition threshold between
low-power and high-power
mode regulator)
IVCC2,Ipeak,r –
–
500 mV IVCC2 = 30mA
VS = 5V
1.9 3.5 mA 2)ICC2 rising;
VS = 13.5V
-40°C < Tj < 150°C
P_7.3.4
P_7.3.15
VCC2 Active Peak Threshold IVCC2,Ipeak,f 0.5 1.3 –
(Transition threshold between
high-power and low-power
mode regulator)
mA 2)ICC2 falling;
VS = 13.5V
-40°C < Tj < 150°C
P_7.3.17
Over Current limitation
IVCC2,lim
100 –
7502) mA
current flowing out of
pin, VCC2 = 0V
P_7.3.5
1) In SBC Stop Mode, the specified output voltage tolerance applies when IVCC2 has exceeded the selected active peak
threshold (IVCC2,Ipeak,r) but with increased current consumption.
2) Not subject to production test, specified by design.
Data Sheet
62
Rev. 1.1, 2014-09-26