9.6
SPI Diagnosis Registers
9.6.1 Standard Diagnosis
BTS54040-LBF
Serial Peripheral Interface (SPI)
SO
7
6
5
4
3
2
1
0
TER
LHI
STB
VSMON ERR_MUX
0
Default
50H
Field
TER
LHI
STB
VSMON
ERR_MUX
Bits
Type Description
6
r
Transmission Error
0B Previous transmission was successful (modulo 8 clocks
received)
1B (default) Previous transmission failed or first transmission after
reset
5
r
Limp Home monitor
0B (default) Normal mode operation
1B Limp Home Mode
4
r
Standby mode monitor
0B Normal mode operation
1B (default) Stand-by mode
3
r
VS monitor
0B (default) VS always > VSMON since last Standard Diagnosis
readout
1B VS < VSMON at least once
2:0
r
Diagnosis of Channel n in error
000B (default) No channel latched OFF
001B Channel one latched OFF
010B Channel two latched OFF
011B Channel three latched OFF
100B Channel four latched OFF
101B Not used
110B Not used
111B More than one channel latched OFF
Data Sheet
57
Rev. 2.1, 2014-12-05