Diagnosis
CS
DCR.MUX 110
IIS
000
tsIS (EN)
001
t sIS(MUX)
Figure 23 Current Sense Multiplexer Timings
110
tdIS (MUX )
t
t
Diagnosis_MuxTiming.emf
8.2.3 Open Load at ON Diagnosis
If a channel is ON in Open Load condition, a small current can still flow, for example because of humidity. The
parameter IL(OL) gives the threshold of recognition for such leakage current. If the voltage measured at the sense
resistor RSENSE corresponds to a current IIS(OL) (4 µA), then the current flowing at the output in ON state is within
the limits given by IL(OL). Figure 24 shows the sense current behavior once a channel in Open Load at ON
condition is selected with the sense current multiplexer. The red curve show a typical product curve. The blue line
shows the ideal kILIS ratio.
IIS
IIS(OL )
IIS(en)
Figure 24 Current Sense Ratio in Open Load at ON condition
IL(OL )
IL
8.3
Switch Bypass Monitor Diagnosis
To detect short circuit to VS, there is a switch bypass monitor implemented. In case of short circuit between the
output pin OUT and VS in ON-state, the current flows through the power transistor as well as through the short
circuit (bypass) with undefined share between the two. As a result, the current sense signal shows lower values
than expected by the load current. In OFF-state, the output voltage remains close to VS potential which leads to a
small VDS.
The switch bypass monitor compares the threshold VDS(SB) with the voltage VDS across the power transistor of that
channel which is selected by the current sense multiplexer (DCR.MUX). The result of the comparison can be read
in SPI register DCR.SBM.