English
Language : 

BTS54040-LBF_15 Datasheet, PDF (24/67 Pages) Infineon Technologies AG – SPI Power Controller
BTS54040-LBF
Power Supply
5.2.1
Undervoltage on VS
Between VS(OP) and VS(UV) the undervoltage mechanism is triggered. If the device is operative and the supply
voltage drops below the undervoltage threshold VS(UV), the logic switches OFF the channels. As soon as the supply
voltage VS is above the minimum operative voltage threshold VS(OP), the channels having either the corresponding
Input pin set to “high” or the OUT.OUTn bit set to “1” are switched ON again (as shown in Figure 12).
VOUT
VS
VS(OP )
VS (UV)
VS(HYS )
Figure 12 VS undervoltage behavior
t
t
PowerSupply _UVRVS .emf
Data Sheet
24
Rev. 2.1, 2014-12-05