Table 11 Electrical Characteristics Diagnosis (cont’d)
Parameter
Symbol
Values
Min.
Typ.
Current sense settling time tsIS(LC)
–
–
after change of load
current
39 mΩ ch.
Max.
25
Current sense settling time tsIS(LC) –
–
25
after change of load
current
39 mΩ ch. in LED mode
Current sense settling time tsIS(EN) –
–
25
after current sense
activation
Current sense settling time tsIS(MUX) –
–
25
after multiplexer channel
change
Current sense deactivation tdIS(MUX) –
–
25
time
Switch Bypass Monitor
Switch bypass monitor
VDS(SB)
1.5
3.3
4.5
threshold
1) Not subject to production test, specified by design.
Diagnosis
Unit
μs
μs
μs
μs
μs
Note /
Number
Test Condition
1)
IL = 2.6 A to 1.3 A
VS = 13.5 V
RIS = 2.7 kΩ
LGCR.LEDn = 0
P_8.5.111
1)
IL = 1.0 A to 0.6 A
VS = 13.5 V
RIS = 2.7 kΩ
LGCR.LEDn = 1
P_8.5.112
RIS = 2.7 kΩ
IL2 = 2.6 A
DCR.MUX: 110B →
001B
RIS = 2.7 kΩ
IL2 = 2.6 A
IL3 = 4 A
DCR.MUX: 001B →
010B
1)
RIS = 2.7 kΩ
DCR.MUX: 010B →
110B
P_8.5.114
P_8.5.115
P_8.5.116
V
OFF state
P_8.5.117
Data Sheet
48