BTS54040-LBF
Diagnosis
8.5
Electrical Characteristics
Unless otherwise specified: VS = 7 V to 18 V, VDD = 3.8 V to 5.5 V, Tj = -40 °C to +150 °C
Typical values: VS = 13.5 V, VDD= 4.3 V, Tj = 25 °C
Typical resistive loads connected to the outputs (unless otherwise specified):
39 mΩ channels: RL = 6.8 Ω (33 Ω when LGCR.LEDn = “1”)
Measurement setup used for kILIS (unless otherwise specified):
When IL ≤ 1.3 A all channels are ON at the same time with equal IL
When IL ≥ 2.0 A only the measured channel is ON, all other channels have IL = 0
Table 10 Electrical Characteristics Diagnosis kILIS 39 mΩ ch.
Parameter
Symbol
Values
Min.
Typ.
Max.
Unit Note /
Test Condition
Current Sense Ratio Signal in the Nominal Area, Stable Load Current Condition
39 mΩ ch.
Current sense ratio
kILIS03
-36 %
2000
+36 %
–
IL03 = 300 mA
Current sense ratio
kILIS05
-29 %
2000
+29 %
–
IL05 = 600 mA
Current sense ratio
kILIS07
-15 %
2000
+15 %
–
IL07 = 1.3 A
Current sense ratio
kILIS09
-12 %
2000
+12 %
–
IL09 = 2.6 A
Current sense ratio
kILIS10
-11 %
2000
+11 %
–
IL10 = 4 A
Current Sense Ratio Signal in the Nominal Area, Stable Load Current Condition
39 mΩ ch. in LED mode
Current sense ratio
kILIS00
-52 %
620
+52 %
–
IL00 = 20 mA
Current sense ratio
kILIS02
-30 %
570
+30 %
–
IL02 = 150 mA
Current sense ratio
kILIS03
-15 %
570
+15 %
–
IL03 = 300 mA
Current sense ratio
kILIS05
-11 %
570
+11 %
–
IL05 = 600 mA
Current sense ratio
kILIS06
-10 %
570
+10 %
–
IL06 = 1 A
Number
P_8.5.49
P_8.5.51
P_8.5.53
P_8.5.55
P_8.5.56
P_8.5.57
P_8.5.59
P_8.5.60
P_8.5.62
P_8.5.63
Data Sheet
45