English
Language : 

XC2288H_11 Datasheet, PDF (119/151 Pages) Infineon Technologies AG – 16/32-Bit Single-Chip Microcontroller with 32-Bit Performance
XC2288H, XC2289H
XC2000 Family / High Line
Electrical Parameters
Table 26 System PLL Parameters
Parameter
Symbol
Min.
VCO output frequency
fVCO CC 50
10
100
20
Values
Typ. Max.
−
110
−
40
−
200
−
80
Unit Note /
Test Condition
MHz VCOSEL= 00b;
VCOmode=
controlled
MHz VCOSEL= 00b;
VCOmode=
free running
MHz VCOSEL= 01b;
VCOmode=
controlled
MHz VCOSEL= 01b;
VCOmode=
free running
FlexRay PLL Parameters
This PLL unit is dedicated for usage with the FlexRay module. FlexRay operation
requires a high precision clock signal to fulfil the protocol timing requirements. If the
system clock is generated by use of a quartz it is mandatory to adjust the quartz
parameters in your target system. Please refer also to Chapter 4.7.3 for details.
Table 27 FlexRay PLL Parameters
Parameter
Symbol
Min.
VCO output frequency
fVCA CC 480
80
Values
Typ. Max.
−
480
−
340
Unit Note /
Test Condition
MHz VCOmode= con
trolled
MHz VCOmode= fre
e running
4.7.2.2 Wakeup Clock
When wakeup operation is selected (SYSCON0.CLKSEL = 00B), the system clock is
derived from the low-frequency wakeup clock source:
fSYS = fWU.
In this mode, a basic functionality can be maintained without requiring an external clock
source and while minimizing the power consumption.
Data Sheet
119
V1.3, 2011-07