English
Language : 

MC9S08QE16CLC Datasheet, PDF (145/350 Pages) Freescale Semiconductor, Inc – Low-power wireless applications, Gas, water and heater meters
ADCH
01000
01001
01010
01011
01100
01101
01110
01111
Analog-to-Digital Converter (S08ADC10V1)
Figure 9-4. Input Channel Select (continued)
Input Select
AD8
AD9
AD10
AD11
AD12
AD13
AD14
AD15
ADCH
11000
11001
11010
11011
11100
11101
11110
11111
Input Select
AD24
AD25
AD26
AD27
Reserved
VREFH
VREFL
Module disabled
9.4.2 Status and Control Register 2 (ADCSC2)
The ADCSC2 register is used to control the compare function, conversion trigger and conversion active
of the ADC module.
7
6
5
4
3
R ADACT
0
ADTRG
ACFE
ACFGT
W
Reset:
0
0
0
0
0
= Unimplemented or Reserved
2
1
0
0
R1
R1
0
0
0
1 Bits 1 and 0 are reserved bits that must always be written to 0.
Figure 9-5. Status and Control Register 2 (ADCSC2)
Table 9-4. ADCSC2 Register Field Descriptions
Field
7
ADACT
6
ADTRG
Description
Conversion Active — ADACT indicates that a conversion is in progress. ADACT is set when a conversion is
initiated and cleared when a conversion is completed or aborted.
0 Conversion not in progress
1 Conversion in progress
Conversion Trigger Select — ADTRG is used to select the type of trigger to be used for initiating a conversion.
Two types of trigger are selectable: software trigger and hardware trigger. When software trigger is selected, a
conversion is initiated following a write to ADCSC1. When hardware trigger is selected, a conversion is initiated
following the assertion of the ADHWT input.
0 Software trigger selected
1 Hardware trigger selected
MC9S08AC60 Series Data Sheet, Rev. 3
Freescale Semiconductor
145