XRT83L314 Datasheet, PDF (68/84 Pages) Exar Corporation – 14-CHANNEL T1/E1/J1 LONG-HAUL/SHORT-HAUL LINE INTERFACE UNIT
XRT83L314
14-CHANNEL T1/E1/J1 LONG-HAUL/SHORT-HAUL LINE INTERFACE UNIT
REV. 1.0.0
TABLE 41: MICROPROCESSOR REGISTER 0XE0H BIT DESCRIPTION
GLOBAL REGISTER (0XE0H)
BIT
NAME
FUNCTION
Register
Type
Default
Value
(HW reset)
D1
GIE Global Interrupt Enable
R/W
0
The global interrupt enable is used to enable/disable all interrupt
activity for all 14 channels. This bit must be set "High" for the inter-
rupt pin to operate.
0 = Disable all interrupt generation
1 = Enable interrupt generation to the individual channel registers
D0
SRESET Software Reset
R/W
0
Writing a "1" to this bit for more than 10µS initiates a device reset
for all internal circuits except the microprocessor register bits. To
reset the registers to their default setting, use the Hardware Reset
pin (See the pin description for more details).
TABLE 42: MICROPROCESSOR REGISTER 0XE1H BIT DESCRIPTION
GLOBAL REGISTER (0XE1H)
BIT
NAME
FUNCTION
Register
Type
Default
Value
(HW reset)
D7
Reserved This Register Bit is Not Used
R/W
0
D6
Reserved This Register Bit is Not Used
R/W
0
D5
GAUGE1 Wire Gauge Select
D4
GAUGE0 00 = 22 and 24 gauge
01 = 22 gauge
10 = 24 gauge
11 = 26 gauge
R/W
0
0
D3
Reserved This Register Bit is Not Used
R/W
0
D2
RxMUTE Receiver Output Mute Enable
R/W
0
If RxMUTE is selected, RPOS/RNEG will be pulled "Low" for any
channel that experiences an RLOS condition. If an RLOS condi-
tion does not occur, RxMUTE will remain inactive.
0 = Disabled
1 = Enabled
64