English
Language : 

XRT8001 Datasheet, PDF (15/48 Pages) Exar Corporation – WAN Clock for T1 and E1 Systems
XRT8001
2.6 The “Forward/Slave” Mode
In the “Forward/Slave” Mode, the XRT8001 will
accept an 8kHz clock signal via the Reference
Clock Input (FIN), and will output a “L x 64kHz or L
x 56kHz” clock signal (where L can range from 1 to
32) via the CLK1 and CLK2 output pins.
Figure 12 presents a simple illustration of the
XRT8001 WAN Clock operating in the “Forward/
Slave” Mode.
8kHz
L x 56kHz
FIN
CLK1
or
L x 64kHz
Where 1 < L < 32
XRT8001
WAN Clock
CLK2
L x 56kHz
or
L x 64kHz
Where 1 < L < 32
Figure 12. Illustration of the XRT8001 WAN Clock
Operating in the “Forward/Slave” Mode
Rev. 1.01
15