English
Language : 

EP2S90F1020C4 Datasheet, PDF (117/238 Pages) Altera Corporation – Section I. Stratix II Device Family Data Sheet
Configuration & Testing
The Quartus II software has an Auto Usercode feature where you can
choose to use the checksum value of a programming file as the JTAG user
code. If selected, the checksum is automatically loaded to the USERCODE
register. Turn on the Auto Usercode option by clicking Device & Pin
Options, then General, in the Settings dialog box (Assignments menu).
Table 3–2. Stratix II Boundary-Scan Register Length
Device
EP2S15
EP2S30
EP2S60
EP2S90
EP2S130
EP2S180
Boundary-Scan Register Length
1,140
1,692
2,196
2,748
3,420
3,948
Table 3–3. 32-Bit Stratix II Device IDCODE
Device
EP2S15
EP2S30
EP2S60
EP2S90
EP2S130
EP2S180
Version
(4 Bits)
0000
0000
0001
0000
0000
0000
IDCODE (32 Bits) (1)
Part Number (16 Bits)
Manufacturer Identity (11
Bits)
LSB (1 Bit) (2)
0010 0000 1001 0001
000 0110 1110
1
0010 0000 1001 0010
000 0110 1110
1
0010 0000 1001 0011
000 0110 1110
1
0010 0000 1001 0100
000 0110 1110
1
0010 0000 1001 0101
000 0110 1110
1
0010 0000 1001 0110
000 0110 1110
1
Notes to Table 3–3:
(1) The most significant bit (MSB) is on the left.
(2) The IDCODE's least significant bit (LSB) is always 1.
1 Stratix, Stratix II, Cyclone, and Cyclone II devices must be
within the first 17 devices in a JTAG chain. All of these devices
have the same JTAG controller. If any of the Stratix, Stratix II,
Cyclone, and Cyclone II devices are in the 18th or after they fail
configuration. This does not affect SignalTap II.
Altera Corporation
May 2007
3–3
Stratix II Device Handbook, Volume 1