English
Language : 

AK4642EN Datasheet, PDF (25/83 Pages) Asahi Kasei Microsystems – Stereo CODEC with MIC/HP/SPK-AMP
ASAHI KASEI
[AK4642EN]
„ PLL Unlock State
1) PLL Master Mode (PMPLL bit = “1”, M/S bit = “1”)
In this mode, LRCK and BICK pins go to “L” and irregular frequency clock is output from MCKO pins at MCKO bit is
“1” before the PLL goes to lock state after PMPLL bit = “0” Æ “1”. If MCKO bit is “0”, MCKO pin goes to “L” (see
Table 7).
After the PLL is locked, a first period of LRCK and BICK may be invalid clock, but these clocks return to normal state
after a period of 1/fs.
When sampling frequency is changed, BICK and LRCK pins do not output irregular frequency clocks but go to “L” by
setting PMPLL bit to “0”.
PLL State
After that PMPLL bit “0” Æ “1”
MCKO pin
MCKO bit = “0” MCKO bit = “1”
“L” Output
Invalid
BICK pin
“L” Output
PLL Unlock (except above case)
“L” Output
Invalid
Invalid
PLL Lock
“L” Output
See Table 9
See Table 10
Table 7. Clock Operation at PLL Master Mode (PMPLL bit = “1”, M/S bit = “1”)
LRCK pin
“L” Output
Invalid
1fs Output
2) PLL Slave Mode (PMPLL bit = “1”, M/S bit = “0”)
In this mode, an invalid clock is output from MCKO pin before the PLL goes to lock state after PMPLL bit = “0” Æ “1”.
After that, the clock selected by Table 9 is output from MCKO pin when PLL is locked. ADC and DAC output invalid
data when the PLL is unlocked. For DAC, the output signal should be muted by writing “0” to DACL, DACH and DACS
bits.
PLL State
After that PMPLL bit “0” Æ “1”
MCKO pin
MCKO bit = “0” MCKO bit = “1”
“L” Output
Invalid
PLL Unlock
“L” Output
Invalid
PLL Lock
“L” Output
Output
Table 8. Clock Operation at PLL Slave Mode (PMPLL bit = “0”, M/S bit = “0”)
MS0420-E-00
- 25 -
2005/09