EVAL-ADPD105Z-GEN Datasheet, PDF (8/26 Pages) Analog Devices – Supports the detection of UART | |||
|
◁ |
UG-1021
HIGH LEVEL
Figure 16 shows the ADPD103_ADPD105 OpenMarket WaveTool
HighLevel configuration window. This window offers an entire
set of high level parameter controls. The configurable
parameters are as follows:
ï· Sampling Frequencyâadjusts the sampling rate.
ï· Internal Average (identical for both timeslots in the
ADPD105)âcontrols the output data rate, which is equal
to the sampling frequency divided by the internal average.
For example, a sampling frequency of 400 Hz and an
internal average setting of 4, as shown in Figure 16, results in
an output data rate of 100 Hz.
ï· ADPD Slot Modeâspecifies all the ADPD105 slot modes.
ï· Slot A Control and Slot B Control
ï· LED Control
ï· LEDâselects an LED from the drop-down menu.
ï· LED Statusâspecifies whether the selected LED
is in the on or off state.
ï· Number Of Pulsesâsets the number of LED
pulses.
ï· TIA Gainâsets the gain of the transimpedance
amplifier (TIA) via a drop-down menu.
EVAL-ADPD105Z-GEN User Guide
ï· Timing Controlâsee the ADPD105 data sheet for
detailed descriptions of the timing controls.
ï· AFE Width (us)âsets the AFE integration time in
microseconds.
ï· Pulse Width (us)âsets the LED pulse width in
microseconds.
ï· Pulse Offset (us)âsets the LED pulse offset in
microseconds.
ï· AFE Offset (us)âsets the coarse AFE integration
offset in microseconds.
ï· AFE Fine Offset (ns)âsets the fine AFE
integration offset in nanoseconds.
ï· LED 1, LED 2, and LED 3 current controls
ï· I_LED Coarseâcoarse setting for the LED current
via the I_LED Coarse drop-down menu.
ï· Scale Factorâ100% or 40% scale factor applied to
the coarse LED current setting.
ï· Final I_LEDâsets Final I_LED current in the
Final I_LED field by using the slider. The field
displays in milliamps.
To switch to the RegisterLevel configuration, click the Go to
RegisterLevel button.
Figure 16. HighLevel Window
Rev. 0 | Page 8 of 26
|
▷ |