ADPD103_ADPD105 OPENMARKET WAVETOOL MAIN WINDOW
The main window has two different modes: register level
(RegisterLevel) and high level (HighLevel), shown in Figure 8
and Figure 16, respectively.
• Register View shows the current register values of the
device. Change register values by entering a hexadecimal
value into the value column of the register view list and
The RegisterLevel configuration window accesses each register
or can load a complete list of registers that are stored in a
configuration file on the PC.
The high level configuration performs a high level
configuration of the ADPD105 without individual register
writes. The high level configuration screen sets up parameters,
for example, such as LED current, number of LED pulses, and
AFE integration time.
USING THE REGISTERLEVEL CONFIGURATION
Figure 8 shows the ADPD105 configuration window in the
RegisterLevel window. The following controls and descriptions
are listed in the configuration window:
• Firmware Version shows the firmware version.
• Config File in Use shows information about the
configuration file that is in use.
press the Enter key.
• Register Field View shows how the register is subdivided
into fields that determine how each bit field is used. For
example, Figure 8 shows the PAD_IO_CTRL, Register 0x02, is
composed of the bit fields INT_POL, INT_DRV, and
INT_ENA to configure the operation of the INT pin.
• Single Register Control allows reading and writing of
individual registers.
• Load a configuration file (.dcfg) by selecting File >
LoadCfg and selecting a .dcfg file included with the
software installation or a custom .dcfg file developed by the
user for a desired configuration.
• Save a configuration file (.dcfg) by selecting File > SaveCfg.
• The Go to HighLevel button switches to the 3 LED’s High
Level Control view.
Figure 8. RegisterLevel Window
Rev. 0 | Page 5 of 26