English
Language : 

EVAL-ADPD105Z-GEN Datasheet, PDF (13/26 Pages) Analog Devices – Supports the detection of UART
EVAL-ADPD105Z-GEN User Guide
Time View
The Time View tab displays the raw data from the ADPD105 in
time domain format. Plot or send the raw data through the
UDP to the host system that is controlled by the UDP Transfer
checkbox in the Time View, which has three controls:
• The UDP on/plot off mode, where the UDP Transfer
checkbox is checked (see Figure 25). In this mode, the data
is sent through the UDP and does not display in the graph.
Figure 25. UDP On/Plot Off Mode
• The UDP off/plot on mode, where the UDP Transfer
checkbox is not selected (see Figure 26). In this mode, the
data displays in the graph but is not sent through the UDP.
UG-1021
Configure the x-axis sample count for graph plotting through
the X-Axis Sample Counts spin box (see Figure 29).
Figure 29. X-Axis Sample Counts Spin Box
Note the minimum value for sample count is limited to 100. If
the sample count is assigned with values smaller than 100, it
automatically corrects to 100.
The Time View tab shows the raw data graph that plots Sample
(Index) vs. LSBs (10^3) data.
The plot of each individual channel is controlled using the
checkboxes, shown in Figure 30. By clicking any checkbox in
the Slot A or Slot B panes, the corresponding channel data is
plotted with the specified color in the Raw Data Channels graph.
Figure 26. UDP Off/Plot On Mode
• The UDP on/plot on mode, where the UDP Transfer
checkbox fill is solid by selecting three consecutive times
(see Figure 27). In this mode, the data is sent through the
UDP and also displays in the graph.
Figure 27. UDP On/Plot On Mode
The UDP Transfer Tool is set up within the
ADPD103_ADPD105 OpenMarket WaveTool package; see the
UDP Transfer Tool section. The UDP Transfer Tool receives the
data from ADPD103_ADPD105 OpenMarket WaveTool and
transfers the data to the assigned UDP port.
To save the raw data into a file, check the Save Raw Data
checkbox, as shown in Figure 28. When the box is checked, the
user is prompted to save the file.
Figure 28. Checkbox to Save Sensor Raw Data to a File
Figure 30. Channel Display Controls
The auto scaling of the Time View graph can be enabled or
disabled by the AutoScaleEnable checkbox (see Figure 31). The
minimum and maximum scale range can also be adjusted while
the auto scale option is disabled.
Figure 31. AutoScaleEnable Control and Scale Range Setting
The average and standard deviation for every channel and sum
of all channels are displayed in the Slot A and Slot B panes (see
Figure 32). These statistics are enabled or disabled by the checkbox
preceded by each label.
Figure 32. Average and Standard Deviation Controls
Rev. 0 | Page 13 of 26