Register View
The Name column in the Register View list displays the register
name as defined by the register map, followed by (in parentheses)
the address in abbreviated hexadecimal format (see Figure 9).
The Value column displays the register value of the corresponding
register in the Name column in full hexadecimal format.
EVAL-ADPD105Z-GEN User Guide
Hovering over a cell in the Value column in the Register View
list shows the delineation of the register fields for that cell (see
Figure 11), whereas hovering over a cell in the Name column
shows a description of the corresponding register.
Figure 11. Register Value List Selection Hover Description
The Register View list has a context-sensitive menu available by
right-clicking anywhere in the Register View list (see Figure 12).
Figure 9. Register View List
Clicking any register in the Register View list reveals the
register categories in the Register Field View list, as shown in
Figure 10. The Register Field View is read only.
Figure 12. Register View Context-Sensitive Menu
By using the context-sensitive menu, it is possible to refresh the
selected register, refresh all registers, or set the selected register
to display in hexadecimal or decimal format. The selected format
remains set, even when the ADPD103_ADPD105 OpenMarket
WaveTool is opened and closed, until the format is reset.
For example, in Figure 13, the Time Slot B offset registers
(CHx_OFFSET_B) display in decimal format but others, such
as LED drive settings (LEDx_DRV), display in hexadecimal
format.
Figure 13. Register View List Values in Decimal and Hexadecimal Format
Register Field View
The Register Field View list is a read-only view to see specific
register field value(s). It automatically tracks the selected
register in the Register View list.
The Register Field View list is composed of two columns,
shown in Figure 14.
Figure 10. Register Field View List
Enter data in cells in the Value column of the Register View list
in either hexadecimal or decimal format. A hexadecimal
number is entered with a 0x prefix to the number, whereas a
decimal number does not include these prefix characters. For
example, entering 0xFF (hexadecimal) or 255 (decimal), results
in the same value written to the register.