UG-1021
Slot AB Dig Int-1 (16 Bits)
16-bit digital integrated sample data displays in the Time View
tab for Time Slot A and Time Slot B. When in the Frequency
View tab, see Figure 39, use the Channel Select drop-down
menu to display the FFT for the selected channel.
Slot A Dig Int-2 (16 Bits)
16-bit digital integrated sample and background data displays in
the Time View tab for Time Slot A only. When in the
Frequency View tab, see Figure 39, use the Channel Select drop-
down menu to display the FFT for the selected channel.
Slot B Dig Int-2 (16-Bits)
16-bit digital integrated sample and background data displays in
the Time View tab for Time Slot B only. When in the Frequency
View tab, see Figure 39, use the Channel Select drop-down
menu to display the FFT for the selected channel.
Slot AB Dig Int-2 (16 Bits)
16-bit digital integrated sample and background data displays in
the Time View tab for Time Slot A and Time Slot B. When in the
Frequency View tab, see Figure 39, use the Channel Select drop-
down menu to display the FFT for the selected channel.
Slot A Dig Int-1 (32 Bits)
32-bit digital integrated sample data displays in the Time View tab
for Time Slot A only. When in the Frequency View tab, see
Figure 39, use the Channel Select drop-down menu to display
the FFT for the selected channel.
Slot B Dig Int-1 32 Bits:
32-bit digital integrated sample data displays in the Time View tab
for Time Slot B only. When in the Frequency View tab, see
Figure 39, use the Channel Select drop-down menu to display
the FFT for the selected channel.
Slot AB Dig Int-1 (32 Bits)
32-bit digital integrated sample data displays in the Time View tab
for Time Slot A and Time Slot B. When in the Frequency View
tab, see Figure 39, use the Channel Select drop-down menu to
display the FFT for the selected channel.
Slot A Dig Int-2 (32 Bits)
32-bit digital integrated sample and background data display in
the Time View tab for Time Slot A only. When in the Frequency
View tab, see Figure 39, use the Channel Select drop-down
menu to display the FFT for the selected channel.
Slot B Dig Int-2 (32 Bits)
32-bit digital integrated sample and background data display in
the Time View tab for Time Slot B only. When in Frequency
View tab, see Figure 39, use the Channel Select drop-down
menu to display the FFT for the selected channel.
EVAL-ADPD105Z-GEN User Guide
Slot AB Dig Int-2 (32 Bits)
32-bit digital integrated sample and background data display in
the Time View tab for Time Slot A and Time Slot B. When in
the Frequency View tab, see Figure 39, use the Channel Select
drop-down menu to display the FFT for the selected channel.
LOAD AND SAVING CONFIGURATIONS
To load and save device configuration files, use File > Load Cfg
and File > Save Cfg, respectively, as shown in Figure 18 and
Figure 19. The load configuration option (Load Cfg) loads the
set of registers contained in the user selected .dcfg file to the
ADPD105. The save configuration option (Save Cfg) saves all
writable registers of the ADPD105 to a .dcfg file via the Open file
dialog box.
Find sample configuration files installed with the
ADPD103_ADPD105 OpenMarket WaveTool application in the
SampleCfgs folder.
Figure 18. Load Configuration
Figure 19. Save Configuration
Selecting Load Cfg opens a file dialog box. Device
configuration files have the extension .dcfg. Once loaded, the
configuration file used by the evaluation board displays in the
RegisterLevel window in the Config File in Use pane, shown
in Figure 8 and Figure 20. The full path of the .dcfg file is shown
when the mouse hovers over the file name. If no file is loaded,
the Config File in Use pane displays None.
Rev. 0 | Page 10 of 26