EVAL-ADPD105Z-GEN Datasheet, PDF (22/26 Pages) Analog Devices – Supports the detection of UART
UG-1021
EVAL-ADPD105Z-GEN User Guide
Run
Open the ADPD103_ADPD105 OpenMarket WaveTool
application and connect the port (see the Port Connection
section). If the bridge is connected, then open the graph view by
selecting View > Graph.
Next, send the play command as 02 00, where
02 = play command
00 = number of parameters
Stop
Open the ADPD103_ADPD105 OpenMarket WaveTool
application and connect the port (see the Port Connection
section). If the bridge is connected, then open the graph view:
View > Graph.
Next, send the stop command as 03 00, where
03 = stop command
00 = number of parameters
Table 2. Commands Summary
Command
Connect
Disconnect
Open view
Load configuration (Load Cfg)
Read
Write
Run
Stop
Raw data
1 See Figure 64.
Command Code1
0A 00
0B 00
0C 00
0D 00
00 01
<reg address>
01 03
<reg address> <Value>
02 00
03 00
06 01 <ON/OFF>
Load Configuration
Open the ADPD103_ADPD105 OpenMarket WaveTool
application and connect the port (see the Port Connection
section). If bridge is connected, then a command can be sent to
the ADPD103_ADPD105 OpenMarket WaveTool through the
UDP.
Next, send the load configuration file command as 0D 00,
which gives a list of available configuration file names, shown in
Figure 64. Select the particular configuration file from the list
shown.
Likewise, commands can be given for connect, disconnect,
open view, and raw data by referring to the command list in
Table 2.
COMMANDS SUMMARY
Table 2 summarizes the list of commands, command code and
example formats for various functions that are currently
available in the ADPD103_ADPD105 OpenMarket WaveTool.
Example
0A 00
0B 00
0C 00
0D 00
00 01 40
01 03 41 00 01
02 00
03 00
06 01 01 (or) 06 01 00
Figure 64. List of .dcfg Files Available in the ADPD103_ADPD105 OpenMarket WaveTool Configuration Directory
Rev. 0 | Page 22 of 26