EVAL-ADPD105Z-GEN Datasheet, PDF (20/26 Pages) Analog Devices – Supports the detection of UART
UG-1021
UDP CONTROLLER TOOL
Open the UDPControllertool (see Figure 61) and complete the
Enter your Host IP Address field. This is the IP address of the
host PC where the ADPD103_ADPD105 OpenMarket
WaveTool is running.
After entering the corresponding IP address, the user can send and
receive commands between the controller and the
ADPD103_ADPD105 OpenMarket WaveTool.
Figure 61. UDPControllertool Window
EVAL-ADPD105Z-GEN User Guide
UDP CONTROLLER APPLICATION TESTING
PROCEDURE
Port Connection
To use the read register or write register functions, the port
must be connected in the ADPD103_ADPD105 OpenMarket
WaveTool. Connect the port using the following steps:
1. Open the ADPD105 OpenMarket WaveTool application.
2. Connect the port by selecting File > Connect. Select either
Auto Connect to automatically select the port or Select
Port to manually select the port.
3. Ensure the UDP control IP address is assigned correctly.
Read Register
After connecting the port, send the register read command as
00 01 <reg address>, for example, send as 00 01 01 to read from
register 0x01 (see Figure 62). The following are the defined read
command components:
• 00 = register read command
• 01 = number of parameters
• 01 = register address
The response is received with the register value.
Figure 62. Read Register Operation
Rev. 0 | Page 20 of 26