English
Language : 

DS90UR908Q_14 Datasheet, PDF (9/33 Pages) Texas Instruments – 5 - 65 MHz 24-bit Color FPD-Link II to FPD-Link Converter
DS90UR908Q
www.ti.com
SNLS317H – SEPTEMBER 2009 – REVISED APRIL 2013
Recommended Timing for the Serial Control Bus
Over 3.3V operating supply and temperature ranges unless otherwise specified.
Symbol
Parameter
Conditions
fSCL
SCL Clock Frequency
Standard Mode
Fast Mode
tLOW
SCL Low Period
Standard Mode
Fast Mode
tHIGH SCL High Period
Standard Mode
Fast Mode
tHD;STA
Hold time for a start or a
repeated start condition,
Figure 12
Standard Mode
Fast Mode
tSU:STA
Set Up time for a start or a
repeated start condition,
Figure 12
Standard Mode
Fast Mode
tHD;DAT Data Hold Time, Figure 12
Standard Mode
Fast Mode
tSU;DAT Data Set Up Time, Figure 12
Standard Mode
Fast Mode
tSU;STO Set Up Time for STOP
Condition, Figure 12
Standard Mode
Fast Mode
tBUF
Bus Free Time Between STOP Standard Mode
and START, Figure 12
Fast Mode
tr
SCL & SDA Rise Time,
Figure 12
Standard Mode
Fast Mode
tf
SCL & SDA Fall Time,
Figure 12
Standard Mode
Fast mode
Min
Typ
Max Units
0
100
kHz
0
400
4.7
us
1.3
us
4.0
us
0.6
us
4.0
us
0.6
us
4.7
us
0.6
us
0
3.45
us
0
0.9
us
250
ns
100
ns
4.0
us
0.6
us
4.7
us
1.3
us
1000 ns
300
ns
300
ns
300
ns
DC and AC Serial Control Bus Characteristics
Over 3.3V supply and temperature ranges unless otherwise specified.
Symbol
Parameter
Conditions
VIH
Input High Level
SDA and SCL
VIL
Input Low Level Voltage
SDA and SCL
VHY
VOL
Iin
tR
tF
tSU;DAT
tHD;DAT
tSP
Cin
Input Hysteresis
SDA RiseTime – READ
SDA Fall Time – READ
Set Up Time — READ
Hold Up Time — READ
Input Filter
Input Capacitance
SDA, IOL = 0.5mA
SDA or SCL, Vin = VDDIO or GND
SDA, RPU = X, Cb ≤ 400pF, Figure 12
See Figure 12
SDA or SCL
Min
0.7*
VDDIO
GND
0
-10
Typ
Max Units
VDDIO
V
0.3*
VDDIO
V
>50
mV
0.36
V
+10
µA
800
ns
50
ns
540
ns
600
ns
50
ns
<5
pF
Copyright © 2009–2013, Texas Instruments Incorporated
Product Folder Links: DS90UR908Q
Submit Documentation Feedback