English
Language : 

LM3S1968 Datasheet, PDF (579/709 Pages) List of Unclassifed Manufacturers – Microcontroller
Stellaris® LM3S1968 Microcontroller
Register 7: PWM Raw Interrupt Status (PWMRIS), offset 0x018
This register provides the current set of interrupt sources that are asserted, regardless of whether
they cause an interrupt to be asserted to the controller. The fault interrupt is latched on detection;
it must be cleared through the PWM Interrupt Status and Clear (PWMISC) register (see page 580).
The PWM generator interrupts simply reflect the status of the PWM generators; they are cleared
via the interrupt status register in the PWM generator blocks. Bits set to 1 indicate the events that
are active; zero bits indicate that the event in question is not active.
PWM Raw Interrupt Status (PWMRIS)
Base 0x4002.8000
Offset 0x018
Type RO, reset 0x0000.0000
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
reserved
IntFault
Type RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
reserved
IntPWM2 IntPWM1 IntPWM0
Type RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit/Field
31:17
16
15:3
2
1
0
Name
reserved
IntFault
reserved
IntPWM2
IntPWM1
IntPWM0
Type
RO
RO
RO
RO
RO
RO
Reset
0x00
0
0x00
0
0
0
Description
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
Fault Interrupt Asserted
Indicates that the fault input is asserting.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
PWM2 Interrupt Asserted
Indicates that the PWM generator 2 block is asserting its interrupt.
PWM1 Interrupt Asserted
Indicates that the PWM generator 1 block is asserting its interrupt.
PWM0 Interrupt Asserted
Indicates that the PWM generator 0 block is asserting its interrupt.
July 15, 2014
579
Texas Instruments-Production Data