PRINCIPLES OF OPERATION
SGLS153 – FEBRUARY 2003
TL16C752B-EP programmer’s guide (continued)
Set flow control threshold to VALUE
Set xmt and rcv FIFO thresholds to VALUE
Read FIFORdy register
Set prescaler value to divide-by-one
Set prescaler value to divide-by-four
Read LCR (03), save in temp1
Set LCR (03) to BF
Read EFR (02), save in temp2
Set EFR (02) to 10 + temp2
Set LCR (03) to 00
Read MCR (04), save in temp3
Set MCR (04) to 40 + temp3
Set TCR (06) to VALUE
Set MCR (04) to temp3
Set LCR (03) to BF
Set EFR (02) to temp2
Set LCR (03) to temp1
Read LCR (03), save in temp1
Set LCR (03) to BF
Read EFR (02), save in temp2
Set EFR (02) to 10 + temp2
Set LCR (03) to 00
Read MCR (04), save in temp3
Set MCR (04) to 40 + temp3
Set TLR (07) to VALUE
Set MCR (04) to temp3
Set LCR (03) to BF
Set EFR (02) to temp2
Set LCR (03) to temp1
Read MCR (04), save in temp1
Set temp2 = temp1 × EF; (x sign here means bit-AND)
Set MCR (04) = 04 + temp2
Read FRR (07), save in temp2
Pass temp2 back to host
Set MCR (04) to temp1
Read LCR (03), save in temp1
Set LCR (03) to BF
Read EFR (02), save in temp2
Set EFR (02) to 10 + temp2
Set LCR (03) to 00
Read MCR (04), save in temp3
Set MCR (04) to temp3 × 7F; (× sign here means bit-AND)
Set LCR (03) to BF
Set EFR (02) to temp2
Set LCR (03) to temp1
Read LCR (03), save in temp1
Set LCR (03) to BF
Read EFR (02), save in temp2
Set EFR (02) to 10 + temp2
Set LCR (03) to 00
Read MCR (04), save in temp3
Set MCR (04) to temp3 + 80
Set LCR (03) to BF
Set EFR (02) to temp2
Set LCR (03) to temp1
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265