English
Language : 

LSM303AGR Datasheet, PDF (58/68 Pages) STMicroelectronics – ultra-low-power 3D accelerometer and 3D magnetometer
Register description
8.28 CLICK_SRC_A (39h)
Table 76. CLICK_SRC_A register
IA
DClick
SClick
Sign
Z
Y
LSM303AGR
X
IA
DClick
SClick
Sign
Z
Y
X
Table 77. CLICK_SRC_A description
Interrupt active. Default value: 0
(0: no interrupt has been generated; 1: one or more interrupts have been generated)
Double-click enable. Default value: 0 (0: double-click detection disabled,
1: double-click detection enabled)
Single-click enable. Default value: 0 (0: single-click detection disabled, 1: single-click
detection enabled)
Click sign. 0: positive detection, 1: negative detection
Z click detection. Default value: 0
(0: no interrupt, 1: Z high event has occurred)
Y click detection. Default value: 0
(0: no interrupt, 1: Y high event has occurred)
X click detection. Default value: 0
(0: no interrupt, 1: X high event has occurred)
8.29 CLICK_THS_A (3Ah)
Table 78. CLICK_THS_A register
-
Ths6
Ths5
Ths4
Ths3
Ths2
Ths1
Ths0
Ths[6:0]
Table 79. CLICK_SRC_A description
Click threshold. Default value: 000 0000
8.30 TIME_LIMIT_A (3Bh)
Table 80. TIME_LIMIT_A register
-
TLI6
TLI5
TLI4
TLI3
TLI2
TLI1
TLI0
TLI[6:0]
Table 81. TIME_LIMIT_A description
Click time limit. Default value: 000 0000
58/68
DocID027765 Rev 5