Register description
8.33 CTRL_REG5_M (24h)
Table 83. CTRL_REG5_M register
0(1) BDU
0(1)
0(1)
0(1)
0(1)
0(1)
1. These bits must be set to ‘0’ for the correct operation of the device.
LSM303C
0(1)
BDU
Table 84. CTRL_REG5_M register description
Block data update for magnetic data. Default value: 0
(0: continuous update; 1: output registers not updated until MSB and LSB have
been read)
8.34 STATUS_REG_M (27h)
Table 85. STATUS_REG_M register
ZYXOR ZOR
YOR
XOR
ZYXDA ZDA
YDA
XDA
ZYXOR
ZOR
YOR
XOR
ZYXDA
ZDA
YDA
XDA
Table 86. STATUS_REG_M register description
X, Y and Z-axis data overrun. Default value: 0
(0: no overrun has occurred;
1: a new set of data has overwritten the previous data)
Z-axis data overrun. Default value: 0
(0: no overrun has occurred;
1: new data for the Z-axis has overwritten the previous data)
Y-axis data overrun. Default value: 0
(0: no overrun has occurred;
1: new data for the Y-axis has overwritten the previous data)
X-axis data overrun. Default value: 0
(0: no overrun has occurred;
1: new data for the X-axis has overwritten the previous data)
X, Y and Z-axis new data available. Default value: 0
(0: a new set of data is not yet available;
1: a new set of data is available)
Z-axis new data available. Default value: 0
(0: new data for the Z-axis is not yet available;
1: new data for the Z-axis is available)
Y-axis new data available. Default value: 0
(0: new data for the Y-axis is not yet available;
1: new data for the Y-axis is available)
X-axis new data available. Default value: 0
(0: a new data for the X-axis is not yet available;
1: a new data for the X-axis is available)
46/53