LSM303C Datasheet, PDF (23/53 Pages) – | |||
|
◁ |
LSM303C
Application hints
5.2
High current wiring effects
High current in wiring and printed circuit traces can be culprits in causing errors in magnetic
field measurements for compassing.
Conductor-generated magnetic fields will add to the Earthâs magnetic field, leading to errors
in compass heading computation.
Keep currents higher than 10 mA a few millimeters away from the sensor IC.