I/O SPACE - BANK2
OFFSET
4
NAME
FIFO PORTS REGISTER
TYPE
READ ONLY
SYMBOL
FIFO
This register provides access to the read ports of the Receive FIFO and the Transmit completion FIFO.
The packet numbers to be processed by the interrupt service routines are read from this register.
REMPTY
RX FIFO PACKET NUMBER
1
0
0
0
0
0
0
0
TEMPTY
TX FIFO PACKET NUMBER
1
0
0
0
0
0
0
0
REMPTY - No receive packets queued in the RX FIFO. For polling purposes, uses the RCV_INT bit in the
Interrupt Status Register.
TOP OF RX FIFO PACKET NUMBER - Packet number presently at the output of the RX FIFO. Only valid
if REMPTY is clear. The packet is removed from the RX FIFO using MMU Commands 6) or 8).
TEMPTY - No transmit packets in completion queue. For polling purposes, uses the TX_INT bit in the
Interrupt Status Register.
TX FIFO PACKET NUMBER - Packet number presently at the output of the TX FIFO. Only valid if
TEMPTY is clear. The packet is removed when a TX INT acknowledge is issued.
Note:
For software compatibility with future versions, the value read from each FIFO register is intended to be
written into the PNR as is, without masking higher bits (provided TEMPTY and REMPTY = 0 respectively).
I/O SPACE - BANK2
OFFSET
6
RCV
0
AUTO
INCR.
0
0
0
NAME
POINTER REGISTER
READ
0
0
ETEN
AutoTx
0
0
POINTER LOW
0
0
TYPE
READ/WRITE
SYMBOL
PTR
POINTER HIGH
0
0
0
0
0
0
POINTER REGISTER - The value of this register determines the address to be accessed within the
transmit or receive areas. It will auto-increment on accesses to the data register when AUTO INCR. is set.
The increment is by one for every byte access, and by two for every word access. When RCV is set the
address refers to the receive area and uses the output of RX FIFO as the packet number, when RCV is
clear the address refers to the transmit area and uses the packet number at the Packet Number Register.
READ bit - Determines the type of access to follow. If the READ bit is high the operation intended is a
read. If the READ bit is low the operation is a write. Loading a new pointer value, with the READ bit high,
generates a pre-fetch into the Data Register for read purposes.
Read-back of the pointer will indicate the value of the address last accessed by the CPU (rather than the
last pre-fetched). This allows any interrupt routine that uses the pointer, to save it and restore it without
affecting the process being interrupted.
The Pointer Register should not be loaded until 400ns after the last write operation to the Data Register to
ensure that the Data Register FIFO is empty. On reads, if IOCHRDY is not connected to the host, the Data
Rev. 11/18/2004