English
Language : 

M16C6C Datasheet, PDF (56/94 Pages) Renesas Technology Corp – RENESAS MCU
M16C/6C Group
5. Electrical Characteristics
Vdet0 (1)
External Power VCC1
0.1 V
t rth
tw(por) (2)
t rth
Voltage detection 0
circuit response time
Vdet0 (1)
Internal
reset signal
1
× 32
fOCO-S
1
× 32
fOCO-S
Notes:
1. Vdet0 indicates the voltage detection level of the voltage detection 0 circuit.
2. When using power-on reset, hold the external power VCC1 at or below the valid voltage (0.1 V) during tw(por), and
then turn it on.
tw(por) is 30 s or more when -20 °C ≤ Topr ≤ 85 °C, and 3000 s or more when -40 °C ≤ Topr < -20 °C.
Figure 5.5 Power-On Reset Circuit Electrical Characteristics
Table 5.16 Power Supply Circuit Timing Characteristics
Symbol
Parameter
td(P-R)
td(R-S)
td(W-S)
Internal power supply stability time when power is on (2)
STOP release time
Low power mode wait mode release time
Condition
Standard
Unit
Min. Typ. Max.
5 ms
150 μs
150 μs
Notes:
1. The measurement condition is VCC1 = 2.7 to 5.5 V and Topr = 25°C.
2. Waiting time until the internal power supply generation circuit stabilizes when power is on.
REJ03B0277-0100 Rev.1.00 Jul.15, 2009
Page 54 of 90