Section 2 Software Specifications when Using the SH72546RFCC, SH72544R, SH72543R, SH72531FCC,
and SH72531
(a) Specifying the Measurement Start/End Conditions
The measurement start/end conditions are specified by using Event Condition 1,2. The [Ch1,2,3]
list box of the [Combination action (Sequential or PtoP)] dialog box can be used.
Table 2.15 Measurement Period
Classification
Selection in
the [Ch1, 2, 3]
list box
Item
Ch2 to Ch1
PA
Ch1 to Ch2
PA
Other than
above
Description
The period from the satisfaction of the condition set in Event
Condition 2 (start condition) to the satisfaction of the condition set
in Event Condition 1 (end condition) is set as the performance
measurement period.
The period from the satisfaction of the condition set in Event
Condition 1 (start condition) to the satisfaction of the condition set
in Event Condition 2 (end condition) is set as the performance
measurement period.
The period from the start of execution of the user program to the
occurrence of a break is measured.
Figure 2.6 [Performance Analysis] Dialog Box
For measurement tolerance,
• The measured value includes tolerance.
• Tolerance will be generated before or after a break.