English
Language : 

SH72544R Datasheet, PDF (29/56 Pages) Renesas Technology Corp – Microcomputer Development Environment System
Section 2 Software Specifications when Using the SH72546RFCC, SH72544R, SH72543R, SH72531FCC,
and SH72531
Table 2.8 Conditions to Be Set (cont)
Classification
[Ch1, 2, 3] list box
(cont)
[Ch4, 5] list box
Item
Description
Ch1 to Ch2 PA
Sets the performance measurement period during
the time from the satisfaction of the condition set in
Event Condition 1 (start condition) to the
satisfaction of the condition set in Event Condition
2 (end condition).
Sets the point-to-point of the internal trace (the start or end condition of
trace acquisition) using Event Conditions 4 and 5.
Don’t care
Sets no start or end condition of trace acquisition.
I-Trace: Ch5 to Ch4
PtoP
Sets the acquisition period during the time from the
satisfaction of the condition set in Event Condition
5 (start condition) to the satisfaction of the
condition set in Event Condition 4 (end condition).
I-Trace: Ch5 to Ch4
PtoP, power-on reset
Sets the acquisition period during the time from the
satisfaction of the condition set in Event Condition
5 (start condition) to the satisfaction of the
condition set in Event Condition 4 (end condition)
or the power-on reset.
• After the sequential condition and the count specification condition of Event Condition 1 have
been set, break and trace acquisition will be halted if the sequential condition is satisfied for
the specified count.
• If a reset point is satisfied, the satisfaction of the condition set in Event Condition will be
disabled. For example, if the condition is satisfied in the order of Event Condition 3, 2, reset
point, 1, the break or trace acquisition will not be halted. If the condition is satisfied in the
order of Event Condition 3, 2, reset point, 3, 2, 1, the break and trace acquisition will be halted.
• If the start condition is satisfied after the end condition has been satisfied by measuring
performance, performance measurement will be restarted. For the measurement result after a
break, the measurement results during performance measurement are added.
• If the start condition is satisfied after the end condition has been satisfied by the point-to-point
of the internal trace, trace acquisition will be restarted.
Rev. 2.00 Jun. 08, 2009 Page 23 of 46
REJ10J1941-0200