English
Language : 

HD404818 Datasheet, PDF (34/100 Pages) Hitachi Semiconductor – 16-digit LCD driver
HD404818 Series
MIS: $00C
MIS2 MIS1 MIS0
t RC selection
Refer to
table 20
MIS
1 Bit 0 Bit
0
0
0
1
1
0
1
1
T *1
t
*1
RC
0.12207 ms
0.24414 ms 0.24414 ms *2
15.625 ms 7.8125 ms
62.5 ms
31.25 ms
Not used
Oscillation circuit
condition
External clock input
Ceramic or crystal
oscillator
—
Notes: 1. The value of t RC applies only when using
a 32.768-kHz oscillator.
2. Only direct transfer.
Figure 13 Miscellaneous Register
Direct Transfer: By controlling the DTON, the MCU can be placed directly from subactive to active
mode. The detailed procedure is as follows:
• Set the DTON flag in subactive mode while LSON = 0.
• Execute the STOP or SBY instruction.
• After the oscillation stabilization time (a fixed value), the MCU will move automatically from subactive
to active mode.
Note that DTON ($020, bit 3) is valid only in subactive mode. When the MCU is in active mode, this flag
is always at reset.
The transition time (tD) from subactive to active mode is tRC < tD < T + tRC.
Interrupt
strobe
STOP/SBY
execution Internal
execution
Subactive mode
time (< T)
(LSON = 0, DTON = 1)
Direct transfer
timing
Oscillation
stabilization
time
Active mode
T
t RC
T: Interrupt frame period
t RC : Oscillation stabilization period
Figure 14 Direct Transfer Timing
MCU Operating Sequence: The MCU operates in the sequence shown in figures 15 to 17. It is reset by an
asynchronous RESET input, regardless of its state.