ICTVÃIngress CLP Transparency Value
This bit determines the value that should be written to a cellÃs header if the ICTEÃIngress CLP Transparency Enable bit is set.
See Section 6 for details.
ICTEÃIngress CLP Transparency Enable
This bit determines whether CLP should be copied to the IOCLPÃIngress Overhead CLP bit and whether the ICTVÃIngress
CLP Transparency Value bit should be written to the cell header CLP. See Section 6 for details.
0 = The ingress header CLP bit is not touched.
1 = CLP should be copied from the cell header to the ingress switch parameters. The ICTVÃIngress CLP Transparency
Value bit should be written to the cell header CLP.
CIMEÃConnection Ingress Marking Enable
This bit enables marking of cells which are received in the ingress. See Section 5.4.3 for details.
0 = Marking of cells which are received in the ingress is disabled.
1 = Marking of cells which are received in the ingress is enabled.
12.2. CONTEXT PARAMETERS TABLE
Some bits have been added, and some bit deÃnitons have been updated in the Egress Parameters Word and the Ingress
Parameters Word. These bits are in bold.
12.2.1. Egress Parameters
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
ECIV EVPC EEOT ESOT ESOO Rsvd ECAS ECRD ECOT ECAO ECSF ECEF ECSB ECEB Rsvd Rsvd
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
ESAI ESRD ESCS ESCE ECA ERA EP6C EP7C EVRE EP6R EP7R
Reserved
EP6RÃEgress PTI 6 Remove
When this bit is set and the CRRP-VC RM cell removal point is set, then an egress cell whose PTI = 6 is removed, provided
that the connection is a VC connection.
EP7RÃEgress PTI 7 Remove
When this bit is set and the RRP-RM cell removal point is set, then an egress cell whose PTI = 7 is removed, provided that the
connection is a VC connection.
EEOTÃEgress End-to-End OAM Termination
When this bit is set, the egress Ãow is treated as the terminating point of the OAM end-to-end cell Ãow for the connection.
Additionally, if the CRRPÃVC RM Cell Removal Point bit is reset, then cells with PTI = 6 or 7 are removed at this point.
12.2.2. Ingress Parameters:
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
ICIV IVPC IEOT ISOT ISOO Rsvd ICAS ICRD ICOT ICAO ICSF ICEF ICSB ICEB Rsvd Rsvd
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
ISAI ISRD ISCS ISCE ICA IRA IP6C IP7C IVRE IP6R IP7R
Reserved
UDT
IP6RÃIngress PTI 6 Remove
When this bit is set and the RRP-RM Cell Removal Point is set, then an ingress cell whose PTI = 6 is removed, provided that
the connection is a VC connection.
IP7RÃIngress PTI 7 Remove
When this bit is set and the RRP-RM Cell Removal Point is set, then an ingress cell whose PTI = 7 is removed, provided that
the connection is a VC connection.
IEOTÃIngress End-to-End OAM Termination
When this bit is set, the ingress Ãow is treated as the terminating point of the OAM end-to-end cell Ãow for the connection.
Additionally, if the CRRPÃVC RM Cell Removal Point bit is reset, then cells which belong to a VC connection and whose PTI =
6 or 7 are removed at this point.