English
Language : 

M37754FFCGP Datasheet, PDF (18/68 Pages) Mitsubishi Electric Semiconductor – SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER FLASH MEMORY VERSION
PRELIMINARY NSootimcee: pTahriasmisentroict alimfinitsalasrpeescuifbicjeactitotno. change.
MITSUBISHI MICROCOMPUTERS
M37754FFCGP
M37754FFCHP
SHINGLE-CHIP 16-BIT CMOS MICROCOMPUTER FLASH MEMORY VERSION
Read-only mode
The microcomputer enters the read-only mode by applying VPPL to
the VPP pin. In this mode, the user can input the address of a
memory location to be read and the control signals at the timing
shown in Figure 8, and the M37754FFCGP and the M37754FFCHP
will output the contents of the user’s specified address from data I/O
pin to the external. In this mode, the user cannot perform any opera-
tion other than read.
VIH
Address
VIL
VIH
CE
VIL
VIH
OE
VIL
tWRR
VIH
WE
VIL
Data
VOH Floating
VOL
Valid address
tRC
ta(CE)
tDF
ta(OE)
tOLZ
tCLZ
ta(AD)
tDH
Dout
Floating
Fig. 8 Read timing
Read/Write mode
The microcomputer enters the read/write mode by applying VPPH to
the VPP pin. In this mode, the user must first input a software com-
mand to choose the operation (e. g., read, program, or erase) to be
performed on the flash memory (this is called the first cycle), and
then input the information necessary for execution of the command
(e.g, address and data) and control signals (this is called the second
cycle). When this is done, the M37754FFCGP and the
M37754FFCHP execute the specified operation.
Table 3 shows the software commands and the input/output informa-
tion in the first and the second cycles. The input address is latched
___
internally at the falling edge of the WE input; software commands
and other input data are latched internally at the rising edge of the
___
WE input.
The following explains each software command. Refer to Figures 9
to 11 for details about the signal input/output timings.
Table 3. Software command (Parallel input/output mode)
Symbol
Read
Program
Program verify
Erase
Erase verify
Reset
Device identification
First cycle
Address input
×
×
×
×
Verify address
×
×
Data input
0016
4016
C016
2016
A016
FF16
9016
Note: ADI = Device identification address : manufacturer’s code 0000016, device code 0000116
DDI = Device identification data : manufacturer’s code 1C16, device code D016
X can be VIL or VIH.
Second cycle
Address input
Data I/O
Read address
Read data (Output)
Program address
Program data (Input)
×
Verify data (Output)
×
2016 (Input)
×
Verify data (Output)
×
FF16 (Input)
ADI
DDI (Output)
18