PIC16(L)F720/721
REGISTER 6-6: PORTB: PORTB REGISTER
R/W-x
R/W-x
R/W-x
R/W-x
U-0
U-0
U-0
U-0
RB7
RB6
RB5
RB4
—
—
—
—
bit 7
bit 0
Legend:
R = Readable bit
-n = Value at POR
W = Writable bit
‘1’ = Bit is set
U = Unimplemented bit, read as ‘0’
‘0’ = Bit is cleared
x = Bit is unknown
bit 7-4
bit 3-0
RB<7:4>: PORTB I/O Pin bit
1 = Port pin is > VIH
0 = Port pin is < VIL
Unimplemented: Read as ‘0’
REGISTER 6-7: TRISB: PORTB TRI-STATE REGISTER
R/W-1
R/W-1
R/W-1
R/W-1
U-0
U-0
U-0
U-0
TRISB7
TRISB6
TRISB5
TRISB4
—
—
—
—
bit 7
bit 0
Legend:
R = Readable bit
-n = Value at POR
W = Writable bit
‘1’ = Bit is set
U = Unimplemented bit, read as ‘0’
‘0’ = Bit is cleared
x = Bit is unknown
bit 7-4
bit 3-0
TRISB<7:4>: PORTB Tri-State Control bit
1 = PORTB pin configured as an input (tri-stated)
0 = PORTB pin configured as an output
Unimplemented: Read as ‘0’
REGISTER 6-8: WPUB: WEAK PULL-UP PORTB REGISTER
R/W-1
R/W-1
R/W-1
R/W-1
U-0
U-0
WPUB7
WPUB6
WPUB5
WPUB4
—
—
bit 7
U-0
U-0
—
—
bit 0
Legend:
R = Readable bit
-n = Value at POR
W = Writable bit
‘1’ = Bit is set
U = Unimplemented bit, read as ‘0’
‘0’ = Bit is cleared
x = Bit is unknown
bit 7-4
bit 3-0
Note 1:
2:
WPUB<7:4>: Weak Pull-up PORTB Control bits
1 = Weak pull-up enabled (1,2)
0 = Weak pull-up disabled
Unimplemented: Read as ‘0’
Global RABPU bit of the OPTION register must be cleared for individual pull-ups to be enabled.
The weak pull-up device is automatically disabled if the pin is in configured as an output.
 2011 Microchip Technology Inc.
Preliminary
DS41430B-page 57