English
Language : 

PIC18F25K20T-ISO Datasheet, PDF (374/456 Pages) Microchip Technology – 28/40/44-Pin Flash Microcontrollers with nanoWatt XLP Technology
PIC18F2XK20/4XK20
26.5 DC Characteristics: Primary Run Supply Current, PIC18F2XK20/4XK20
PIC18F2XK20/4XK20
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C  TA  +125°C
Param
No.
Device Characteristics
Typ Max Units
Conditions
D014
D014A
Supply Current (IDD)(1, 2)
0.25 0.45
0.50 0.75
mA -40°C to +125°C
mA -40°C to +125°C
VDD = 1.8V
VDD = 3.0V
FOSC = 1 MHz
(PRI_RUN,
EC oscillator)
D015
D015A
2.7 3.2 mA -40°C to +125°C VDD = 2V
4.3 5.0 mA -40°C to +125°C VDD = 3.0V
FOSC = 20 MHz
(PRI_RUN,
EC oscillator)
D016
12.2 14.0 mA -40°C to +85°C VDD = 3.0V
FOSC = 64 MHz
(PRI_RUN,
EC oscillator)
D017
D017A
2.1 2.9 mA -40°C to +125°C VDD = 1.8V
FOSC = 4 MHz
16 MHz Internal
4.2 5.0 mA -40°C to +125°C VDD = 3.0V (PRI_RUN HS+PLL)
D018
12.2 15.0 mA -40°C to +85°C
VDD = 3.0V
FOSC = 16 MHz
64 MHz Internal
(PRI_RUN HS+PLL)
Note 1:
2:
The supply current is mainly a function of operating voltage, frequency and mode. Other factors, such as
I/O pin loading and switching rate, oscillator type and circuit, internal code execution pattern and
temperature, also have an impact on the current consumption.
The test conditions for all IDD measurements in active operation mode are:
All I/O pins set as outputs driven to Vss;
MCLR = VDD;
OSC1 = external square wave, from rail-to-rail (PRI_RUN and PRI_IDLE only).
26.6 DC Characteristics: Primary Idle Supply Current, PIC18F2XK20/4XK20
PIC18F2XK20/4XK20
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C  TA  +125°C
Param
No.
Device Characteristics
Typ Max Units
Conditions
D019
D019A
Supply Current (IDD)(1, 2)
0.05 0.07
0.09 0.15
mA -40°C to +125°C
mA -40°C to +125°C
VDD = 1.8V
VDD = 3.0V
FOSC = 1 MHz
(PRI_IDLE mode,
EC oscillator)
D020
D020A
1.2 1.6 mA -40°C to +125°C VDD = 2.0V
1.8 2.5 mA -40°C to +125°C VDD = 3.0V
FOSC = 20 MHz
(PRI_IDLEmode,
EC oscillator)
D021
5.6 7.0 mA -40°C to +85°C VDD = 3.0V
FOSC = 64 MHz
(PRI_IDLEmode,
EC oscillator)
Note 1:
2:
The supply current is mainly a function of operating voltage, frequency and mode. Other factors, such as
I/O pin loading and switching rate, oscillator type and circuit, internal code execution pattern and
temperature, also have an impact on the current consumption.
The test conditions for all IDD measurements in active operation mode are:
All I/O pins set as outputs driven to Vss;
MCLR = VDD;
OSC1 = external square wave, from rail-to-rail (PRI_RUN and PRI_IDLE only).
DS41303G-page 374