MAX14830_15 Datasheet, PDF (60/68 Pages) Maxim Integrated Products – Quad Serial UART with 128-Word FIFOs
MAX14830
Quad Serial UART with 128-Word FIFOs
S
SCL
Sr
P
SDA
Figure 21. I2C START, STOP, and Repeated START Conditions
Table 12. I2C Address Map
MOSI/A1
DGND
DGND
DGND
DGND
VL
VL
VL
VL
SCL
SCL
SCL
SCL
SDA
SDA
SDA
SDA
CS/A0
DGND
VL
SCL
SDA
DGND
VL
SCL
SDA
DGND
VL
SCL
SDA
DGND
VL
SCL
SDA
UART0
WRITE
READ
0xD8
0xD9
0xC2
0xC3
0xC4
0xC5
0xC6
0xC7
0xC8
0xC9
0xCA
0xCB
0xCC
0xCD
0xCE
0xCF
0xD0
0xD1
0xD2
0xD3
0xD4
0xD5
0xD6
0xD7
0xC0
0xC1
0xDA
0xDB
0xDC
0xDD
0xDE
0xDF
UART1
WRITE
READ
0xB8
0xB9
0xA2
0xA3
0xA4
0xA5
0xA6
0xA7
0xA8
0xA9
0xAA
0xAB
0xAC
0xAD
0xAE
0xAF
0xB0
0xB1
0xB2
0xB3
0xB4
0xB5
0xB6
0xB7
0xA0
0xA1
0xBA
0xBB
0xBC
0xBD
0xBE
0xBF
UART2
WRITE
READ
0x58
0x59
0x42
0x43
0x44
0x45
0x46
0x47
0x48
0x49
0x4A
0x4B
0x4C
0x4D
0x4E
0x4F
0x50
0x51
0x52
0x53
0x54
0x55
0x56
0x57
0x40
0x41
0x5A
0x5B
0x5C
0x5D
0x5E
0x5F
UART3
WRITE
READ
0x38
0x39
0x22
0x23
0x24
0x25
0x26
0x27
0x28
0x29
0x2A
0x2B
0x2C
0x2D
0x2E
0x2F
0x30
0x31
0x32
0x33
0x34
0x35
0x36
0x37
0x20
0x21
0x3A
0x3B
0x3C
0x3D
0x3E
0x3F
condition (P), to relinquish control of the bus, or a
Repeated START condition (Sr) to communicate to anoth-
er I2C slave. See Figure 21.
Slave Address
The MAX14830 includes a 7-bit I2C slave address, allowing
up to 16 MAX14830 devices to share the same I2C bus.
The address is defined by connecting the MOSI/A1 and CS/
A0 inputs to ground, VL, SDA or to SCL (Table 12). Set the
read/write bit to 1 to configure the MAX14830 to read mode.
Set the read/write bit to 0 to configure the MAX14830 to
write mode. The address is the first byte of information sent
to the MAX14830 after the START condition.
www.maximintegrated.com
Maxim Integrated │  60