RF Coax Connectors
Coaxial Cables
List of the coaxial cables that are listed in the various
connector series of this section.
Characteristic
Impedance (Ω)
50
50
50
50
50
50
50
50
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
Max. Cable
Outer Diameter (mm)
1.9
2.1
2.25
2.6
2.8
3.0
3.6
6.4
2.67
3.0
3.3
3.2
3.6
4.0
4.0
4.8
5.0
6.1
6.2
6.25
7.8
9.8
9.8
Dielectric Diameter (mm)/
Material1)
0.91max/PTFE
0.87/PTFE
1.71max/PTFE
1.60max/PTFE
1.60max/PE
1.52/PTFE
3.01max/PTFE
5.38max/PTFE
1.68max/PTFE
1.60max/PTFE
1.68max/Cell-FEP
2.1max
2.0max/Cell-PE
2.0maxE/Cell-PE
2.54max/PE
2.54max/PE
2.54max/PE
4.25max/PE
2.83max/PE
3.8max/PE
4.43max/PE
6.4/PE
6.4/PE
Cable-Type Designation
VDE Designation2)
US Designation
Manufacturer des.
5YC5Ye 0.3/0.86
RG 178
—
RG 196
5YK 0.51/1.68
RG 405
5YC5Ye 0.5/1.5
RG 316
2YCY 0.5/1.5
RG 174
5YCC5Y 0.5/1.5
RD 316
5YK 0.9/3.0
RG 402
5YK 1.63/5.33
RG 401
5YC6Y 0.3/1.6
RG 179
—
RD 179
06YCC(St)6Y 0.4/1.6
—
—
ST 212
02Y(St)CY 0.45/2.0
—
02Y12YC(mS)C6Y 0.45/2.0 —
2YCY 0.4/2.5
—
2YCCY 0.4/2.5
—
2YC(mS)CY 0.4/2.5
—
2YCY 0.7/4.4
—
2YC(mS)CY 0.5/3.0
—
2YCY 0.58/3.7
RG 59
2YCCY 0.7/4.4
—
2YCCY 1.0/6.5
—
2YC(mS)CY 1.0/6.5
—
1) Material label
PTFE
Polytetrafluorethylene
PE
Polyethylene
FEP
Perfluorethylene propylene
PFA
Perfluoralkoxy copolymer
2) Mounting label of the VDE type numbers (from inside to outside)
Example:
IEC Designation
96-IEC
50-1-1
50-1-2
—
50-2-1
—
—
—
—
75-2-1
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Explanation
Dielectric and Jacket
2Y = PE
5Y = PTFE
02Y = Cell PE
06Y = Cell FEP
6Y = FEP
Screen:
C = Cu braiding
K = Cu tape
Intermediate layer:
mS = magnetic screen
St = static screen
Specifications on inner
conductor:
vs = silver plated
staku = Bare copper-clad
steel wire
conductor
Jacket color:
gn = green
gr = grey
rt = red
ws = white
6Y C (mS) C
Y 0.7/4.0 -75 (r2/100) vs gr
Dielectric
1st screen
Intermediate layer
2nd screen
Outer jacket
Diameter inner conductor/dielectric
Characteristic impedance
Max. reflection (r) in % / frequency in MHz
Specifications on inner conductor and/or jacket color
Catalog 1307191
Revised 3-07
www.tycoelectronics.com
Dimensions are in millimeters
and inches unless otherwise
specified. Values in brackets
are standard equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
151
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-8706-080-208