English
Language : 

X3102 Datasheet, PDF (7/32 Pages) Intersil Corporation – 3 Cell Li-Ion Battery Protection and Monitor IC
Capacitance TA = +25°C, f = 1MHz, VRGO = 5V
SYMBOL
PARAMETER
COUT (Note 8) Output capacitance (SO)
CIN (Note 8) Input capacitance (SCK, SI, CS)
NOTE:
8. This parameter is not 100% tested.
Equivalent A.C. Load Circuit
5V
SO
3025Ω
2061Ω
30pF
X3102
CONDITIONS
VOUT = 0V
VIN = 0V
A.C. Test Conditions
Input pulse levels
Input rise and fall times
Input and output timing level
MAX
8
6
UNITS
pF
pF
0.5 – 4.5V
10ns
2.5V
A.C. Characteristics (Over the recommended operating conditions, unless otherwise specified.)
Serial Input Timing
SYMBOL
PARAMETER
MIN
MAX
UNITS
fSCK
Clock frequency
0
3.3
MHz
tCYC
Cycle time
300
ns
tLEAD
CS lead time
150
ns
tLAG
CS lag time
150
ns
tWH
Clock HIGH time
130
ns
tWL
Clock LOW time
130
ns
tSU
Data setup time
20
ns
tH
Data hold time
20
ns
tRI (Note 9)
Data in rise time
2
µs
tFI (Note 9)
Data in fall time
2
µs
tCS
CS deselect time
100
ns
tWC (Note 10)
Write cycle time
5
ms
NOTES:
9. This parameter is not 100% tested.
10. tWC is the time from the rising edge of CS after a valid write sequence has been sent to the end of the self-timed internal nonvolatile write cycle.
Serial Input Timing
CS
tLEAD
tCS
tLAG
SCK
SI
tSU
tH
MSB IN
tRI
tFI
LSB IN
SO
7
FN8246.0
December 22, 2004