English
Language : 

X40231 Datasheet, PDF (31/36 Pages) Intersil Corporation – Triple Voltage Monitors, POR, 2 kbit EEPROM MEMORY, and Single/Dual DCP
X40231, X40233, X40235, X40237, X40239
POTENTIOMETER CHARACTERISTICS
Limits
Symbol
Parameter
Min. Typ. Max. Units
Test Conditions/Notes
RTOL
End to End Resistance Tolerance
-20
In a ratiometric circuit, RTOTAL
+20
%
divides out of the equation and
accuracy is determined by XDCP
resolution.
VRHx
VRLx
PR
RW
IW
RH Terminal Voltage (x = 0,1,2)
RL Terminal Voltage (x = 0,1,2)
Power Rating(1)
DCP Wiper Resistance
Wiper Current
Noise
Absolute Linearity(2)
Relative Linearity(3)
RTOTAL Temperature Coefficient
Ratiometric Temperature
Coefficient
VSS
VSS
-1
-1
200
400
±300
±300
VCC
VSS
10
5
400
1200
4.4
+1
+1
±30
V
V
mW
mW
Ω
Ω
mA
mV
√(Hz)
mV
√(Hz)
MI(4)
MI(4)
ppm/°C
ppm/°C
ppm/°C
RL Terminal internally tied to gnd.
RTOTAL = 10kΩ (DCP0, DCP1)
RTOTAL = 100kΩ (DCP2)
VCC = 5 V, VRHx = VCC,
VRLx = VSS (x = 0,1,2),
IW = 50 uA /500 uA (100/10kΩ).
VCC = 2.7 V, VRHx = VCC,
VRLx = VSS (x = 0,1,2),
IW = 27 uA /270 uA (100/10 kΩ).
RTOTAL = 10kΩ (DCP0, DCP1)
RTOTAL = 100kΩ (DCP2)
Rw(n)(actual) - Rw(n)(expected)
Rw(n+1) - [Rw(n) + MI]
RTOTAL = 10kΩ (DCP0, DCP1)
RTOTAL = 100kΩ (DCP2)
(Voltage divider configuration)
CH/CL/
CW
twr
Potentiometer Capacitances
Wiper Response time
10/10/25
200
pF
See Figure 26.
µs
See Figure 34.
Notes: 1. Power Rating between the wiper terminal RWX(n) and the end terminals RHX VSS - for ANY tap position n, (x = 0,1,2).
Notes: 2. Absolute Linearity is utilized to determine actual wiper resistance versus, expected resistance = (Rwx(n)(actual) - Rwx(n)(expected)) = ±1
Ml Maximum (x = 0,1,2).
Notes: 3. Relative Linearity is a measure of the error in step size between taps = RWx(n+1) - [Rwx(n) + Ml] = ±0.2 Ml (x = 0,1,2)
Notes: 4. 1 Ml = Minimum Increment = RTOT / (Number of taps in DCP - 1).
Notes: 5. Typical values are for TA = 25°C and nominal supply voltage.
Notes: 6. This parameter is periodically sampled and not 100% tested.
31
FN8115.0
April 11, 2005